2000 Agilent Technologies
Automatic Barcode Reader
13
Figure 14
Cable connections for dual head, multidrop automatic bar code reader
1
Configure the Scanner cables
in the Stand-Alone configuration first to
program the Microscan 610 BCR heads. Refer to
Figure 15
. Label the
ADP-232 / BCR Scanners sets as number 1, number 2, ect. Connect the
CPU Interface cable (E7200-61709) from the Com Port 3 (Port 1 on Series
3) on the 5DX to the first ADP-232 J4 connector.
Figure 15
Model 5DX Stand-alone BCR Configuration
2
Power on the BCR ADP-232.
The Scan Head should generate a
continuous series of raster scan lines. Position the scan head towards the
standard bar code label at a distance of about 2.0" (50mm) and verify that
the raster scans across the length of the bar code label. Also check the
power status “green” indicator light is lit. If the code can be read from the
610-0018
BCR
SCANNER
ADP
RS-232
UNIT
POWER
SUPPLY
J4 TO J05051 CABLE
BCR/ADP CABLE
BCR/ADP CABLE
SYSTEM CONTROLLER
EXPAN.CHASSIS