Switch/Load Unit and Plug-In Cards
3
E6198B Switch/Load Unit User Manual
3-23
Fuse Ratings
Fuses are incorporated inside E6198B Switch/Load Unit. There
are 10 fuses and 7 fuses for Standalone SLU and Integrated SLU
respectively. Please refer
Table 3-11
for more detail.
DC Power Bus Connections
PB1 to PB4 are the DC power bus connections as seen in
Figure 3-11
for the standalone unit. Notice the protective cable
enclosure covering both the power bus cabling and power sense
cabling for better protection.
For the integrated unit, there is no protective cable enclosure,
and the cabling would need to be configured by the user directly
onto the backplane, behind the SLU backcover.
Table 3-11
Fuses Ratings
Standalone
Integrated
Description
Fuse1
Fuse1
1A, -12V
Fuse2
Fuse2
6A, +12V_1
Fuse3
Fuse3
6A, +12V_2
Fuse4
Fuse4
Not Used
Fuse5
Fuse5
15A, +5V_1
Fuse6
Fuse6
15A, +5V_2
Fuse7
Fuse7
Not Used
Fuse8
-
30A, PB2
Fuse9
-
30A, PB3
Fuse10
-
30A, PB4