Switch/Load Unit and Plug-In Cards
3
E6198B Switch/Load Unit User Manual
3-19
J1 Pinout
Table 3-7
shows pinout of J1 Frame Select & Spare Supply (SS).
Frame 0 is selected if FS0 and FRAME both are connected;
Frame 1 is selected if FS1 and FRAME both are connected, and
so on. Default setting is frame 0 (zero). More detail about SS
(Spare Supply), please refer .
J2 Pinout
Table 3-8
show pinouts of J2 ISENSE Bussed/Split. Default
setting for J2 is ISENSE Bussed.
J3 Pinout
Table 3-9
shows pinouts of Power Bus Sense Local/Remote.
Local 1 is selected if LOC_S1 is connected with PB1; Remote 1 is
selected if REM_S1 is connected with PB1, and so on. Default
setting for J3 is Local.
Table 3-7
Switch/Load Unit J1 Pinout
FS1
FS3
FS5
FS7
NC
GND
SS
FS0
FS2
FS4
FS6
FRAME
GND
SS
Table 3-8
Switch/Load Unit J2 Pinout
IS(-2)
IS(+2)
IS(-3)
IS(+3)
IS(-4)
IS(+4)
NC
IS(-1)
IS(+1)
IS(-2)
IS(+2)
IS(-3)
IS(+3)
NC
Table 3-9
Switch/Load Unit J3 Pinout
LOC_S1
PB2
REM_S2
LOC_S3
PB4
REM_S4
LOC_S1
PB1
REM_S1
LOC_S2
PB3
REM_S3
LOC_S4
PB1
Summary of Contents for E6198B
Page 10: ...x E6198B Switch Load Unit User Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 198: ...7 10 E6198B Switch Load Unit User Manual 7 Using the Custom Card Figure 7 8 E8794A Schematic...
Page 313: ...G 1 Agilent TS 5000 E6198B Switch Load Unit User Manual Agilent Technologies Glossary Of Terms...