Unique Setup & Configurations
Chapter
8
Backflush parameters
The following parameters control backflush events. Determine the desired value for each
parameter.
Parameter
Function
Range
u1
Water flush time in seconds. The default value of this parameter
is 0. When configuring a backflush,
u1
must be assigned a
value (1-10 seconds).
0 – 15
A1
The air injection may be extended beyond the pre-assigned 3
seconds. A1 is assigned with the time added to the default. If the
required Air time is 5 seconds, set
A1
to 2 (3sec d 2
additional seconds).
0 – 15
Strip
This setup enables
Afimilk MPC
system to control a strip mechanism.
The sequence of events at the end of milking with the strip function configured is
illustrated below: