Group 2 – System parameters
Shortcut
Number
Symbol
Parameter
Range
Units
Parameter Type
1
SL
0–15
Seconds
Sweep Duration
2
CH
0–4
Seconds
Cleaning mode: time milk
valve is open each cycle
3
CL
0–99
Seconds
Cleaning mode: time milk
valve is closed each cycle
4
Lb
Lb/Kg
-
Weight Unit
5
tU
C°/F°
-
Temperature Unit
6
U1
0–15
Seconds
Backflush Water time
7
A1
0–15
Seconds
Backflush Air time
8
SM
0–99
Minutes
Sleep Mode Delay
Group 3 – Production parameters
Shortcut
Number
Symbol
Parameter
Range
Units
Parameter Type
1
CU
0 - 4
Number
Flow Controlled
Pulsation: Program
selection
2
F3
0 - 15
Seconds
Vacuum to Removal
Delay
3
Ct
0 - 30
Sec. X 30
Maximum milking time
4
Sd
0 - 5
Seconds
Start to Vacuum Delay
5
IP
4 - 20
Seconds
Delay
Removal Alert Fresh cow
OR Standalone system
6
CC
0 - 99
Seconds
Cluster Clearance Delay
Summary of Contents for MPC 3
Page 1: ......
Page 2: ......
Page 3: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 14: ......
Page 31: ...Figure 8 Layout of Vacuum and Clean air Lines For Milk Meter Solenoids...
Page 32: ......
Page 64: ......
Page 80: ......
Page 96: ...Chapter 8 Unique Setup Configurations MPC Extender Connections Diagram...
Page 98: ......
Page 110: ...Chapter 11 Systems Accessories AfiMilk MPC Installation Manual 110...
Page 113: ...AfiMilk MPC Installation Manual 113 Parts List Chapter 12...