AfiMilk MPC
Installation Manual
74
Chapter
7
First Time Operation
8.
Hold the air gauge in a vertical position and
allow air admission via claw orifice. Write
down the air intake the gage measures. This measurement will be used for calibrating
the “G” parameter value as described below.
Repeat measurement procedure at each milking point.
Adjusting calibration value per air intake
Adjust the value of
G
&
H
parameters in each milk meter according to air admission measured,
per the table below.
Air Admission in the
Cluster
(Liters per minute)
G value for calibration
H value for
calibration
6–7
40
30
7–8
46
37
8–10
49 (default)
40
11–13
55
46
14–17
60
50
18–20
65
55
To adjust
G
&
H
parameters follow this procedure:
o
Ensure that
Afimilk MPC
is in wash mode
(
wash LED illuminated
).
o
Type
2580
and press
to access programming mode.
o
Press Group access number -
4
to enter Calibration Group
o
G
is the first parameter in the group and its value will appear after a short delay.
o
Press
-
G
flashes indicating that editing is enabled.
o
Type the desired value.
o
Press
to confirm.
o
Scroll down to the second parameter in the group –
H
and change its value in the
same manner as explained above.
o
Press
to confirm.
o
When done, press
twice to exit editing mode.
Summary of Contents for MPC 3
Page 1: ......
Page 2: ......
Page 3: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 14: ......
Page 31: ...Figure 8 Layout of Vacuum and Clean air Lines For Milk Meter Solenoids...
Page 32: ......
Page 64: ......
Page 80: ......
Page 96: ...Chapter 8 Unique Setup Configurations MPC Extender Connections Diagram...
Page 98: ......
Page 110: ...Chapter 11 Systems Accessories AfiMilk MPC Installation Manual 110...
Page 113: ...AfiMilk MPC Installation Manual 113 Parts List Chapter 12...