AfiMilk MPC
Installation Manual
85
Unique Setup & Configurations
Chapter
8
Sleep Mode
In cold
environments, sleep mode is used to protect
Afimilk MPC
meters. Sleep mode
keeps
Afimilk MPC
control panels warm by maintaining the circuit under power, without
activating the valve and pulsation outputs.
Setup
To enable Sleep mode
SM
parameter is set to the delay time for entering this mode.
Delay time may be set to 15 to 99 minutes (The default value of
SM
is 0 =
Sleep Mode
disabled
).
SM
parameter is in parameters group 2 (system parameters). Refer to either one of the
changing parameters chapters above (From
AfiFarm
OR directly at the control box) for
exact setting instructions of
SM
.
Operation
If Sleep mode is enabled,
Afimilk MPC
shuts its output down automatically after a delay
time without electronic input OR keyboard being pressed.
Afimilk MPC
returns to its normal operation and display if:
o
Any keyboard button is pressed
o
Any communication message from the
afimilk
computer
o
A “Session Start” command sent from the PC
NOTE
To operate Sleep Mode ensure that power to the milk meters
stays ON between milking sessions even when vacuum and milk
pumps are off!
Summary of Contents for MPC 3
Page 1: ......
Page 2: ......
Page 3: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 14: ......
Page 31: ...Figure 8 Layout of Vacuum and Clean air Lines For Milk Meter Solenoids...
Page 32: ......
Page 64: ......
Page 80: ......
Page 96: ...Chapter 8 Unique Setup Configurations MPC Extender Connections Diagram...
Page 98: ......
Page 110: ...Chapter 11 Systems Accessories AfiMilk MPC Installation Manual 110...
Page 113: ...AfiMilk MPC Installation Manual 113 Parts List Chapter 12...