Chapter
6
Laying Cables and Connecting Wires
Communication Cable
Afimilk MPC
communication is of RS485 type. Communication cables should support this
type of protocol.
afimilk
offers a suitable cable (part number
4097324
) designated for connecting the RS485
communication port of several products to the
Computer. The cable provides 3-wire connection
and shielding for harsh electrical environments.
The cable has one twisted pair and a single
additional conductor. It also provides a drain wire
that allows easier connection of the shield. The
twisted pair of wires transmits and receives the
communication signals. The single conductor runs
the communication ground reference.
This shielded core is protected with a heavy-duty jacket.
Laying Communication Cables
Afimilk MPC
communication is based on a single line “daisy chain” type connection. This
means that a single communication cable “collects” all the devices on the line to a single
Communication Port in the PC.
The example below demonstrates a 64 point parlor connection.
After laying cables, connect wires as described in the following section.
Twisted pair
Single
conductor
Drain Wire
Shield
Aluminum
Summary of Contents for MPC 3
Page 1: ......
Page 2: ......
Page 3: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 14: ......
Page 31: ...Figure 8 Layout of Vacuum and Clean air Lines For Milk Meter Solenoids...
Page 32: ......
Page 64: ......
Page 80: ......
Page 96: ...Chapter 8 Unique Setup Configurations MPC Extender Connections Diagram...
Page 98: ......
Page 110: ...Chapter 11 Systems Accessories AfiMilk MPC Installation Manual 110...
Page 113: ...AfiMilk MPC Installation Manual 113 Parts List Chapter 12...