AfiMilk MPC
Installation Manual
89
Unique Setup & Configurations
Chapter
8
Blood Detection with
AfiLab
installed
Description
In parlors where
AfiLab
is inst
alled, clusters are automatically removed when blood is
detected in the milk. Simultaneously, an announcement appears on the
Afimilk MPC
control box.
Both features need to be configured in
Afifarm
program.
Activation
Three parameters define
automatic cluster
removal at blood
detection. The three
parameters are accessed
via AfiControl's
parameter programming
utility.
To enable the option:
o
Check the mark at "
Blood Removal Enable
"
o
Set the value of "
Blood Removal Threshold
"
o
Set protection level (The way to continue milking after connecting a bucket) at "
LO-
Blood
"
WARNING
After re-attachment of the cluster, the system will no longer alert OR
detach even if blood continue to contaminate the milk. This allows
milking to a separation bucket!