AfiMilk MPC
Installation Manual
66
Chapter
7
First Time Operation
5.
Press
-
F5
flashes indicating that editing is enabled.
6.
Type the desired value.
7.
Press
to confirm the change OR
to cancel the change.
After editing and saving all the parameters requiring change in the group, press
to
return to general programming mode. From this mode you may navigate to another
group by entering the group number (1, 2, 3, or 4).
Parameter Groups definitions
The following tables specify parameters in each group and their shortcut access numbers.
Group 1 – Cow parameters
Shortcut
Number
Symbol
Parameter
Range
Units
Parameter Type
1
F1
1-50
Sec. X 10
Minimal Milking T for
First Attachment
2
F2
6-50
Seconds
Valve opening interval
to trigger removal
3
F5
0-12
Sec. X 10
Second Attachment
Premilk Time
4
PP
List
ppm
Pulsation Rate
5
Pr
List
%
Pulsation Ratio
6
StP
List
ppm
Stimulation PPM
7
Sd
0-99
Seconds
Stimulation Duration
8
Str
List
%
Stimulation Operation
Ratio
9
AP
0- 10
No. of Pulses
Pulsation ratio of
50:50 for number of
pulses at the
beginning of milking
-
St
0-50
Seconds
Strip Threshold
-
F4
0/1
Enable/Disable Quick Removal
Summary of Contents for MPC 3
Page 1: ......
Page 2: ......
Page 3: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 14: ......
Page 31: ...Figure 8 Layout of Vacuum and Clean air Lines For Milk Meter Solenoids...
Page 32: ......
Page 64: ......
Page 80: ......
Page 96: ...Chapter 8 Unique Setup Configurations MPC Extender Connections Diagram...
Page 98: ......
Page 110: ...Chapter 11 Systems Accessories AfiMilk MPC Installation Manual 110...
Page 113: ...AfiMilk MPC Installation Manual 113 Parts List Chapter 12...