24
For Technicians | AfiPass II Installation Guide
Table 9 – Grommet Usage
Grommet
Hole
Cable
Connector
A
1
24VAC Power
J10
2
PC COMM. RS485 In
J1
3
PC COMM. RS485 Out
J2
B
1
Gates Exit I
J4
2
Gates Entry I
J4
3
Gates Exit II
J5
C
1
2
3
Gates Entry II
J5
Antenna 1
ANT1
Grounding wire
Screw to PCB
D
1-3
Not used.
E
1
Antenna 2
ANT2
2
Antenna 3
ANT3
F
1-3
Not used
G
1
Antenna 4
ANT4
2
Antenna 5
ANT5
7.4
Wiring the Cables to the Connectors
The AfiPass II Controller is comprised of the following two separate Electrical PCBs (printed circuit
boards):
•
Control PCB mounted to the chassis of the controller's case.
•
Display PCB mounted to the case's front panel. The two boards are connected via flat cable.