26
For Technicians | AfiPass II Installation Guide
Connector
Cable
Connects to
Wires for Afimilk source cables
Device
Connection
J5
Input
(2x2-wire)
Ex.II & En.II
Entry and exit gates
from side II
1
Either entry II gate wire
2
Either entry II gate wire
3
Either exit II gate wire
4
Either exit II gate wire
J7
Signal
(3-wire)
IO or Comm
Future application
IO RS485 port
1
GND (Blue)
2
B (White)
3
A (Yellow)
J8
Flat cable
(10 wire)
Display Panel PCB J1 in Display PCB
prewired
J10
Power
(2-wire)
24VAC IN
24VAC input cable
from Transformer
1
AC~
2
AC0
ANT1-5
RF Signal
(Coax.
cable)
Antennas outputs
antennas
1
Shield
2
Wire