ISDN TESTER AND ANALYZER D2000
PRO
/D2000Lite/D2000 USER’S MANUAL
Note that:
The LED
RUN
goes on and the START key changes to STOP. Use this key to stop
the test.
To obtain the access configuration, the instrument makes a series of calls to the
entered number, changing the profile and the B channel every time, and tries to
verify the supplementary services.
Following are some examples of “RESULT: ACCESS TEST” screens.
4
Scroll through the result pages.
Page 1 shows information about the called number and the status of layers 1and 2.
In a P-P connection, the configuration Master/Slave is automatically detected.
Page 2 shows an overview of the tele- and bearer services available. The last row
displayed on this page shows the availability on the access of a second protocol.
Only for bi-protocol network (E-DSS1/1TR6).
The instrument makes a series of calls to the entered number, each time with a
different profile.
For calls to a remote number:
►
The
LOCAL
column shows the services enabled at the local access for the
selected channel.
►
The
REM
column shows the services enabled at the remote access for the
selected channel.
For autocalls:
►
The
OUT
column shows the services enabled at the local access for outgoing
calls.
►
The
IN
column shows the services enabled at the local access for incoming
calls.
28
CHAPTER 2 - PERFORMING AN AUTOMATIC TEST
Summary of Contents for D2000 Lite
Page 1: ...ISDN TESTER AND ANALYZER D2000 USER S MANUAL ISDN TESTER AND ANALYZER D2000 USER S MANUAL...
Page 170: ...ISDN TESTER AND ANALYZER D2000 PRO D2000Lite D2000 USER S MANUAL APPENDIX A 170 APPENDIX A...
Page 177: ...USER S MANUAL ISDN TESTER AND ANALYZER D2000 PRO D2000Lite D2000 APPENDIX B APPENDIX B 177...
Page 185: ...USER S MANUAL ISDN TESTER AND ANALYZER D2000 PRO D2000Lite D2000 APPENDIX C APPENDIX C 185...