Setup the device in Monitor mode
2
Go into the Monitor results page. According to the
instructions reported in the previous chapters
3
Select ‘Bch’ softkey
4
Configure the parameters
B channel capture
: Choose the B channel to capture.
•
No
, the instrument disables the capture on B channel
•
Bx
, the instrument captures the Bx channel selected
•
Automatic
, the instrument captures the first B channel activated. As soon as
the network release the channel, the device stops capturing.
Max length
: Inset the maximum number of bytes to save. The smaller is the value,
the bigger is the quantity of packets that is possible to save into the internal memory
of the device. To obtain a long trace is suggested to use PC108 for Windows™ or the
MultiMediaCard™ optino MMC2000.
Other B channel capture
: It is possible to enable the capturing of a second B
channel among the left ones.