The duration of each call can be determined with the time values
shown: in ISDN use the time values between SETUP and
DISCONNECT, in POTS between OFF HOOK and ON HOOK
events.
8.5. Analyzing a Trace in Mix Decoding Mode
From the full decoding mode you can display the trace in mix decoding mode as
follows:
1
Select an event. The screen changes to the mix decoding
mode.
The screen displays all information on the selected message, indicating the octet
value and the length of each single message.
2
Scroll through the pages with information on the selected
message.
3
Select another message.
To return to the overview mode:
4
Return to the overview mode.
To go to the hexadecimal decoding mode:
5
Change decoding mode.
134