66
Chapter 3
www.aerotech.com
3.3.1. Analog Output 1 (TB202)
The analog output is set to zero when power is first applied to the system or during a system reset.
N O T E :
The Soloist MP does not have an "Analog Output 0".
Table 3-7:
Analog Output 1 Specifications (TB202)
Specification
Value
Output Voltage
-5 V to +5 V
Output Current
5 mA
Resolution (bits)
16 bits
Resolution (volts)
153 µV
Table 3-8:
Port 1 Analog Output Pins on the Analog I/O Connector (TB202)
Pin#
Description
In/Out/Bi
1
Analog Common
N/A
4
Analog Output 1
Output
Figure 3-4:
Analog Output 1 Connector (TB202)
Soloist MP
-IO Expansion Board