![Aerotech Ndrive HP 10 User Manual Download Page 86](http://html1.mh-extra.com/html/aerotech/ndrive-hp-10/ndrive-hp-10_user-manual_2863043086.webp)
Ndrive HP 10/20/30 User’s Manual
Options
www.aerotech.com
4-11
4.1.7. Opto-Isolated Inputs (TB305)
The inputs are configured for 5-24 volt logic, using a higher input voltage, requires
adding external series resistors to limit the current. The opto-isolator is a PS2506L-4
device. The inputs may be connected to current sourcing or current sinking devices, as
shown in Figure 4-11 and Figure 4-12. Each 4-bit bank of inputs (0-3 or 4-7) must be
connected to either all current sourcing or all current sinking devices. Also, note in the
table below, that inputs 0-3 and inputs 4-7 have two different common inputs, pin 1 and
pin 2, respectively. See Section 3.3.1 for opto-isolated EOT limit inputs.
Table 4-11.
Opto-Isolated Input Connector Pin Assignment (TB305)
Pin #
Label
Description
In/Out/Bi
1
C0-3
Input Common for inputs 0 - 3
Input
2
C4-7
Input Common for inputs 4 - 7
Input
3
Input 0
Input 0 (Optically-Isolated) – See pin 1
Input
4
Input 1
Input 1 (Optically-Isolated) – See pin 1
Input
5
Input 2
Input 2 (Optically-Isolated) – See pin 1
Input
6
Input 3
Input 3 (Optically-Isolated) – See pin 1
Input
7
Input 4
Input 4 (Optically-Isolated) – See pin 2
Input
8
Input 5
Input 5 (Optically-Isolated) – See pin 2
Input
9
Input 6
Input 6 (Optically-Isolated) – See pin 2
Input
10
Input 7
Input 7 (Optically-Isolated) – See pin 2
Input
Figure 4-11.
Inputs Connected in Current Sinking Mode
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com