Isolated Signals
This output signal is a fully-isolated 5-24V compatible output capable of sourcing or sinking
current. This output is normally open and only conducts current when a PSO fire event occurs.
The PSO Isolated Outputs are overload protected and will turn off if the maximum output
current is exceeded.
Figure 3-10:
PSO Output Sources Current
Figure 3-11:
PSO Output Sinks Current
TTL Signals
This output signal is a 5V TTL signal which is used to drive an opto coupler or general purpose
TTL input. This signal is active high and is driven to 5V when a PSO fire event occurs.
Figure 3-12:
PSO TTL Outputs Schematic
3.5. PSO Interface [-EB1]