2.5.3. Digital Outputs
Optically-isolated solid-state relays drive the digital outputs. You can connect the digital outputs in
current sourcing or current sinking mode but you must connect all four outputs in the same
configuration. Refer to
and
You must install suppression diodes on digital outputs that drive relays or other inductive devices. To
see an example of a current sourcing output that has diode suppression, refer to
. To see
an example of a current sinking output that has diode suppression, refer to
The digital outputs are not designed for high-voltage isolation applications and they should only be
used with ground-referenced circuits.
The digital outputs have overload protection. They will resume normal operation when the overload
is removed.
Table 2-37:
Digital Output Specifications
Digital Output Specifications
Value
Maximum Voltage
24 V (26 V Maximum)
Maximum Sink/Source Current
250 mA/output
Output Saturation Voltage
0.9 V at maximum current
Output Resistance
3.7 Ω
Rise / Fall Time
250 µs (2K pull up to 24V)
Reset State
Output Off (High Impedance State)
Table 2-38:
Digital Output Pins on the Auxiliary I/O Connector
Pin#
Description
In/Out/Bi
7
Digital Output 0
Output
8
Digital Output 1
Output
9
Digital Output 2
Output
15
Digital Output Common
Output
16
Digital Output 3
Output
2.5.3. Digital Outputs
iXC6e/XC6e Hardware Manual
64