![Aerotech Automation1 iXC6e Hardware Manual Download Page 31](http://html1.mh-extra.com/html/aerotech/automation1-ixc6e/automation1-ixc6e_hardware-manual_2863025031.webp)
The list that follows includes suggestions for inrush limiter bypass contactors. You can also use
devices that are not on the list, but they must be rated for the system voltage / current and must be
in accordance with local electrical safety requirements.
Manufacturer P/N
Description
CA7-40-E-M40-24E
4 Pole, 37A, 24VDC coil
CA7-60D-00-24DD
3 Pole, 60A, 24VDC coil
CA7-72D-00-24DD
3 Pole, 60A, 24VDC coil
CA7-85D-00-24DD
3 Pole, 60A, 24VDC coil
CA7-97D-00-24DD
3 Pole, 60A, 24VDC coil
The list that follows includes time delay accessories for the CA7 series contactors. The contactor may
also be controlled by software or other logic that monitors the motor supply levels and provides the
desired delay.
Manufacturer P/N
Description
CRE7-3-24/48VDC
0.1 to 3 second adjustable turn on delay
CRE7-30-24/48VDC
1 to 30 second adjustable turn on delay
iXC6e/XC6e Hardware Manual
2.1.4. Inrush Current Limiting
www.aerotech.com
31