RN200 Mono Software User Manual
14
(a) Uplink OTA test (with signal analyzer) (b) Downlink OTA test (with signal generator)
Figure 10: Active/ non-signaling RF test system diagram (with test instrument)
Cables connection instructions:
1.
Connect the LAN ports of the RN200, signal analyzer, signal generator to a network
switch; then connect the control PC to the network switch with an RJ45 cable.
2.
Use a USB cable and connect the device’s USB Type-B port on the interface panel with a
USB port on the control PC.
Connect the uplink/downlink signals of the signal analyzer/signal generator to the SPDT
(RF switch), and connect the two output ports of SPDT to the H and V ports of The RN200.
Note: When using the external instruments, users must prepare the test instrument and SPDT,
and program the test software by themselves.