GPIB OPERATION
4-36
SEQT
:PARAM (continued)
:TGAP
Set DTMF inter-element gap
Data type :
Decimal Numeric Program Data
Allowed suffices :
MS
Default suffix :
MS
:EDIT
[not used alone]
:TNUM
Select Number of Tone to Edit
Data type :
Decimal Numeric Program Data
Allowed suffices :
None
Default suffix :
None
:TFRQ
Set Tone Frequency of tone selected by TNUM
Data type :
Decimal Numeric Program Data
Allowed suffices :
Any one of: GHZ, MHZ, KHZ or HZ
Default suffix :
HZ
:TDUR
Set Normal Tone Duration
:TGAP
Set Inter-element Gap
Data type :
Decimal Numeric Program Data
Allowed suffices :
MS
Default suffix :
MS
:LOAD
Losad a Standard to TEMP for editing
Data type :
Character Program Data (any one of: CCIR, EURO, DZVEI, ZVEI1, ZVEI2,
EEA, EIA, NATEL, USER1 or USER2)
Allowed suffices :
None
Default suffix :
None
:SAVE
Copy TEMP to USER1 or USER2
Data type :
Character Program Data (either USER1 or USER2)
Allowed suffices :
None
Default suffix :
None
Examples:
SEQT:SEQ "12245B7";DUR "----E--"
SEQT:MODE STD CCIR;MOD TOTAL_FM
SEQT:PARAM:EXTD 200MS;SHFT 0.5PCT
SEQT:EDIT:TNUM 3;TFRQ 1342.7HZ;SAVE USER1
SEQT?
Prepares message containing information on the signalling sequence and
duration settings in the following format:
:SEQT:SEQ <toneseq>;DUR <durseq>
where: <toneseq> is string program data defining the tone sequence
and <durseq> is string program data defining the duration
sequence.
Examples:
:SEQT:SEQ "12245B7";DUR "----E--"
:SEQT:SEQ "12345*#9"
(DTMF ONLY)
SEQT:MODE?
Prepares message containing information on the signalling standard and
the modulation channel selected in the following format:
:SEQT:MODE:STD <standard>;MOD <modchannel>
where: <standard> is a program mnemonic defining the tone standard
and <modchannel> is character program data defining the
modulation channel allocated to tone signalling.
Example:
:SEQT:MODE:STD ZVEI;MOD TOTAL_FM