GPIB OPERATION
4-23
ADVANCED DIGITAL
(continued)
:LEAK
:VALUE
Set carrier leakage error (short form)
Set carrier leakage error
Data type :
Decimal Numeric Program Data
Allowed suffices :
PCT
Default suffix :
PCT
:ON
Turn on IQ carrier leakage error
:OFF
Turn off IQ carrier leakage error
Data type :
None
Allowed suffices :
None
Default suffix :
None
:EXT_SER
[not used alone]
:DATAPOL
Select external serial data and specify the data polarity
Data type :
Character Program Data (either NORMAL or INVERSE)
Allowed suffices :
None
Default suffix :
None
:BITSTAT
Select external serial data and specify the bit clock status
Data type :
Character Program Data (either INTERNAL or EXTERNAL)
Allowed suffices :
None
Default suffix :
None
:EXT_SER
:BITPOL
Select external serial data and specify the bit clock polarity
Data type :
Character Program Data (either POS_EDGE or NEG_EDGE)
Allowed suffices :
None
Default suffix :
None
:SYMSTAT
Select external serial data and specify the symbol clock status
Data type :
Character Program Data (either INTERNAL or EXTERNAL)
Allowed suffices :
None
Default suffix :
None
:SYMPOL
Select external serial data and specify the symbol clock polarity
Data type :
Character Program Data (either POS_EDGE or NEG_EDGE)
Allowed suffices :
None
Default suffix :
None
:EXT_PAR
[not used alone]
:DATAPOL
Select external paralled data and specify the data polarity
Data type :
Character Program Data (either NORMAL or INVERSE)
Allowed suffices :
None
Default suffix :
None
:EXT_PAR
:SYMSTAT
Select external parallel data and specify the symbol clock status
Allowed suffices :
None
Default suffix :
None
:SYMPOL
Select external parallel data and specify the symbol clock polarity
Data type :
Character Program Data (either POS_EDGE or NEG_EDGE)
Allowed suffices :
None
Default suffix :
None
:INT_0S
[not used alone]
:DATAPOL
Select internal "all-zeros" data and specify the data polarity
Data type :
Character Program Data (either NORMAL or INVERSE)
Allowed suffices :
None
Default suffix :
None
:CLOCK
Select internal "all-zeros" and specify the clock source
Data type :
Character Program Data (any one of: INT_SYM, EXT_SYM, EXT_BIT)
Allowed suffices :
None
Default suffix :
None
ADVANCED DIGITAL
(continued)
:INT_0S
:CLOCKPOL
Select internal "all-zeros" and specify the clock polarity
Data type :
Character Program Data (either POS_EDGE or NEG_EDGE)