„AERO” ,Sp. z o.o.
SECTION 3
AT-3 R100
EMERGENCY PROCEDURES
SEPTEMBER, 2004
Page 3-5
AEROPLANE FLIGHT MANUAL
In case of fire in the electrical system
•
Maintain airspeed IAS = 120 km/h / 75 mph / 65 kts
•
Electrical equipment
OFF
•
Fire extinguisher (if fire is in the cabin)
TO BE USED
•
Cabin canopy vents
KEEP OPEN
•
If the fire persists, decide upon a place for landing.
3.5. Gliding flight
•
Recommended aeroplane
configuration
Wing flaps retracted
•
Airspeed
IAS = 120 km/h / 75 mph / 65 kts
•
Throttle
IDLE
•
Gliding ratio (No power)
8
3.6. Emergency landing
3.6.1. Precautionary landing
•
Landing place
IDENTIFY
•
Wing flaps to 40º
EXTEND
•
Maintain approach airspeed
IAS = 100 km/h / 62 mph / 54 kts
•
Safety belts
FASTEN FIRMLY
•
Electrical equipment
OFF
•
Locks of the canopy
UNLOCK
Before touch-down:
•
Fuel valve
PULL SHUT
•
Battery and generator
OFF
•
Ignition switch
OFF
•
Levelling out directly before touchdown. After touching-down, keep
control stick fully pulled.