SECTION 7
“AERO” Sp. z o.o.
DESCRIPTION OF THE AEROPLANE
AT-3 R100
AND ITS EQUIPMENT
Page 7-30
JULY, 2010
AEROPLANE FLIGHT MANUAL
7.13.2. Carburettor heating installation
Closing of the air flow from the cold air inlet causes suction of the hot
air from the engine compartment through the heat exchanger located
above the muffler. The heated air is channelled through the air duct to
the filter box, where the air streams are mixed. The cold air stream
can be adjusted by the flap controlled by the Bowden cable and knob
located on the middle console. The temperature of the carburettor
intake air can be read from the gauge on the instrument panel.
To increase of the temperature turn the knob to the left to unlock and
pull to the selected position and turn right to lock.
1. Heat exchanger
2. Duct
3. Air filter box
4. Air intake
5. Carburettors
6. Middle console
7. Carburettor heating control knob
9