„AERO” Sp. z o. o.
SECTION 4
AT-3 R100
NORMAL PROCEDURES
SEPTEMBER, 2004
Page 4-3
AEROPLANE FLIGHT MANUAL
- Check the sensor of pitot and static pressure is clean
- Check the sediment tanks of the pitot and static pressure systems in
the following way:
- Unscrew the caps.
- Check the caps are dry (if not, evacuate the sediment)
- Screw on and tighten the caps onto the sediment tanks.
- Check condition and cleanliness of radio antennas.
- Visually check condition of the stabilisers and control surfaces.
- Visually check condition and secure fixing of the safety belts.
- Check free and smooth movement of the flight control system i.e. the
elevator, rudder, ailerons and wing flaps, and check it for significant
play or excessive friction.
- Check the levers controlling the engine move smoothly.
- Visually check condition of all board instruments.
- Check condition of battery and of the electric system.
- BATTERY switch
ON
- Indication of voltammeter
CHECK
- Turn indicator, artificial horizon
CHECK
- Radio equipment
CHECK
The battery is serviceable if the voltammeter reads not less than 12 V.