21.05 - 6068956_00
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM
EN
KEY
FUNCTION
ALARMS KEY
Displays the list of alarms and the alarms log;
MENU ACTIVATION KEY
• Pressing this key activates navigation among the menus;
MENU EXIT KEY
• Pressing this key leads to the display of the previous window;
NAVIGATION KEY (+)
• Pressing this key during navigation through the menus/
parameters, allows to pass to the next menu/parameter;
• Pressing this key during parameter modification, increases
the value of the parameter modified;
NAVIGATION KEY (ENTER)
• Pressing this key during navigation through the menus,
allows to enter the selected menu;
• Pressing this key during navigation through the parameters,
allows to select the parameter displayed and enter the mod-
ification mode;
• Pressing this key during parameter modification, confirms
the modification to the value of the parameter selected;
NAVIGATION KEY (-)
• Pressing this key during navigation through the menus/
parameters, allows to pass to the previous menu/parameter;
• Pressing this key during parameter modification, decreases
the value of the parameter modified;
User interface (pGD1)
The NRP unit control panel allows quick se� ng
of the machine functi oning parameters and their
display.
The display is made up from a graphical matrix
with 132 x 64 pixel in order to signal the type of
functi oning, displaying set parameters and any
alarms that have intervened.
All default se� ngs and any modifi cati ons are
memorised in the board.
With the installati on of the PGD1 remote panel,
all of the functi ons and se� ngs available on the
machine can be replicated at a distance.
A� er a power cut, the unit can re-start automati -
cally keeping the original se� ngs.
The user interface is represented by a graphic dis-
play with six keys for navigati on.
The displays are organised via a menu hierarchy,
which can be acti vated by pressing the navigati on
keys. The default for displaying these menus is
represented by the main menu.
Navigati on between the various parameters takes
place using the arrow keys positi oned on the right
side of the panel. These keys are also used to
modify the parameters selected.
INTERFACE CONTROL KEYS
Control keys
Control keys
WARNING
Tampering of parameters contained in the assistance and the manufacturer menu
can cause unit malfunctioning. It is therefore recommended that these parameters
are modifi ed only by authorised staff.
ATTENTION
The
2-pipe
is set up for the producti on of
cooled water, hot water and Domesti c Hot
Water (D.H.W.).
- No Anti -legionella Cycle is included
The
4-pipe
is set up for the producti on of
cooled water and hot water.
11.
USER INTERFACE(PGD1)