ELECTRICAL
7-190
Intermittent power supply
The connector of the charging system becomes
loose.
Poor connection of the battery cable.
Poor connection or short-circuit of the
discharging system.
Poor connection or short-circuit of the power
generation system.
Charging system does not operate properly
Burnt fuse.
Poor contact, open or short circuit.
Regulator/Rectifier malfunctions
AC Generator malfunctions
Engine does not crank smoothly
Primary winding circuit.
Poor ignition coil.
Poor connection of cable and connectors.
Poor main switch.
Secondary winding circuit.
Poor ignition coil.
Poor spark plug.
Poor ignition coil cable.
Current leakage in the spark plug.
Incorrect ignition timing.
AC Generator malfunctions.
Improper installation of CPS.
ECU malfunctions.
Weak starter motor
Poor charging system.
The battery is not fully charged
Poor connection in the windings
The motor gear is jammed by foreign material
Starter motor is working, but engine does not
crank
Poor starter motor pinion.
The starter motor runs in reverse direction.
Poor battery.
Summary of Contents for 350cc
Page 11: ...GENERAL INFORMATION 1 11...
Page 32: ...CVT SYSTEM 3 32...
Page 43: ...ENGINE 4 43 ENGINE SERVICE ENGINE EXPLODED VIEW 1...
Page 44: ...ENGINE 4 44 ENGINE EXPLODED VIEW 2...
Page 45: ...ENGINE 4 45...
Page 46: ...ENGINE 4 46 ENGINE COOLING SYSTEM COOLING SYSTEM EXPLODED VIEW...
Page 53: ...ENGINE 4 53 TOP END DISASSEMBLY...
Page 60: ...ENGINE 4 60...
Page 74: ...ENGINE 4 74...
Page 103: ...ELECTRONIC FUEL INJECTION 5 103 FUELTANK...
Page 168: ...ELECTRICAL 7 168...
Page 171: ...ELECTRICAL 7 171...
Page 191: ...ELECTRICAL 7 191...
Page 192: ...ELECTRICAL 7 192...