5
56
Remark:
The suffix letter “S” stands for standard version and “A” stands for advanced version. The advanced
version possesses the standand features and also provides Wiegand and RS-232 data outputs for the
custom projects with external controller and PC.
Please contact your local agent for the optional devices.
OPTIONAL DEVICES FOR SYSTEM EXPANSION
The Optional Decoders Available for Split-decoded Operation
DA-2800
– Full Feature Decoder with RF Remote Control
DA-2801
– Full Feature Decoder
The Auxiliary Reader / Keypad Available for Multi-station Operation
AR-2802S or A
– EM Card Reader
AR-2806S or A
– EM Card Reader with Digital Keypad
AR-2807S or A
-- EM Card Reader with Digital Keypad
AR-2809S
-- EM Card Reader with Digital Keypad
(D) DURESS OUTPUT
The Duress Output switches to (-) ground when duress code is entered. You may use it to turn
ON an LED lamp and/ or a small buzzer to notify a guard; or connect it to a 24 hour Normally
Open protection zone of an alarm system.
Only one connection option is recommended. Make sure that the sink current does not
exceed the maximum rating of 100mA.
(E) OUTPUT 2 (DK-2836A)
( i ) Shunting an N.C. Zone
Use the Normally Open (N.O.) output contact to shunt a Normally Closed (N.C.) protection zone of an
alarm system.
Set output contact to Start / Stop Mode (Programming Option 52, Output Mode=0).
Use the (N.O.) or (N.C.) output contact to make arm-disarm control of an alarm system.
Consult your alarm control panel manual for the appropriate output contact for arm-disarm control.
Usually set output 2 to Momentary mode (Programming Option 521, Location 52, Output Mode=1) for
multi station systems and Start / Stop mode (Programming Option 520, Location 52, Output Mode=0)
for single station systems.
( ii ) Alarm System Arm-Disarm Control
N.C. OR N.O.