5) To program a new Master Code to replace the old one. See “
Record A Master Code
”
stated at
“Location 01” for the details.
NOTE:
The keypad will set itself to normal operation mode 1 minute after power-up if the Egress Button is
not pressed and the DAP code is not keyed in. To set keypad back to power-up mode, repeat
procedures 1-4.
SYSTEM REFRESHING WITH “REFRESHING CODE” --- 9 9 9 9
The keypad can be refreshed by cleaning all the programmed old data and set it back to default
values except the
Master Code
.
REFRESHING CODE VALIDATION
NOTE:
a)
b)
c)
15
Make sure that system refreshing is really required before entering the refreshing code.
Refreshing takes few minutes. The status LED (amber) keeps flashing during refreshing.
The keypad is back to its default value after refreshing. Re-program of the desired values are
necessary.
46
SYSTEM
CODES
FUNCTION
CODE ENTRY
RESULTS
0 0 0 0
system in programming Mode at the first
Factory Set Master Code for User to set
time.
THIS IS NOT A PERMANENT SYSTEM
CODE & IT IS CHANGED IF A NEW
MASTER CODE IS PROGRAMMED.
OR
NEW MASTER CODE
System in
Programming Mode
9 9 9 9
REFRESH CODE
-- Refresh the system
and set all its function back to default
values.
All programmed
data are cleared
and back to the
default values
except the Master
Code
2 8 2 8
DAP CODE
-- Direct access to
programming mode. Valid only in the
power-up delay period
System in
Programming Mode
0 9 9 9
USER Codes / Cards whole group
clearing Code for the selected Location
LOCATIONS
:
10--- User Group 1
20--- User Group 2
40--- Vistor Group
41--- Duress Group 1
42--- Duress Group 2
LOCATION NO.
Whole group
of users in the
selected location
are cleared
* *
Exit Programming Code
The system back
to normal opration
after programming
DIRECT ACCESS TO PROGRAMMING MODE WITH “DAP” CODE -- 2 8 2 8
In case the Master Code is forgotten, apply the following procedures precisely to set keypad
into programming mode with DAP code:
1)
2)
3)
4)
Switch OFF all the power for 1 minute to ensure that the keypad is fully discharged.
Switch ON power again. The keypad is in Power-up Mode for 1 minute. The buzzer gives
continuous beeps and the Status LED is flashing. This is the only time frame to accept the DAP
code.
Press the Egress Button (the button connecting accross EG IN, (Terminal 11) and (-)GND,
(Terminal 12) once to enable the keypad for accepting DAP code. The power-up beep stops after
the Egress Button is pressed.
Key in the DAP code and validate it with (or ). The Status LED is
ON and the keypad is in programming mode like using Master Code. It is ready to accept new
programming data as long as you like until exit programming mode.
PRESS ONCE
EGRESS BUTTON DAP CODE VALIDATION
Pacifier Tone ON-OFF
7 1
FUNCTION MODE:
0---NO Notification
2---2 Short Beeps
1---1 Second Long Beep
FUNCTION MODE:
0---OFF
1---ON
FUNCTION MODE:
0---OFF
1---ON
FUNCTION MODE
Mode = 1,
ON
7 2
Output Announcer
FUNCTION MODE
7 3
Standby LED Flashing
FUNCTION MODE
Mode = 1,
Flashing ON
Mode = 1
1 Second
Long Beep
Pacifier Tone
8 0
Door Forced Open
Warning & Time
FUNCTION MODE / TIME:
0---OFF
1-999 Seconds
FUNCTION / TIME
Mode = 0,
Door Forced
Open
Warning OFF
8 1
Propped-up Warning &
Time
FUNCTION / TIME
Mode = 0,
Propped-up
Warning OFF
9 0
Egress Delay Warning
CODE 1
CODE 2
Mode = 1
Momentary,
No warning
TIME = 0
No Delay
9 4
Operation Mode
FUNCTION MODE:
MODE
Mode = 0
Keypad
Mode
1---Server Mode
0---Keypad Mode
CODE 1
-
FUNCTION
MODE:
1---Momentary, No warning
2---Momentary, with
warning
3---Momentary, with
w Alarm
4---Hold Contact, No
warning
5---Hold Contact, with
warning
6---Hold Contact, with
w Alarm
CODE 2
-
DELAY TIME:
0---No Delay
1-99 Seconds