background image

LOCATION

PARAMETERS

DEFAULT FUNCTIONS & VALUES

0 1

Master Code

0 0 0 0 Factory Set, Not a default value *

0 2

Super User Codes

Nil ----- User Program Required

0 3

Common User Code 1

Nil ----- User Program Required

0 4

Common User Code 2

 

Nil ----- User Program Required

1 0

User Codes & Cards for O/P 1

Nil ----- User Program Required

2 0

User Codes & Cards for O/P 2

Nil ----- User Program Required

4 0

Visitor Codes

 

Nil ----- User Program Required

4 1

Duress Code for O/P 1

 

Nil ----- User Program Required

4 2

Duress Code for O/P 2

 

Nil ----- User Program Required

5 1

O/P Mode of The O/P 1

Time = 5 Sec, Momentary

5 2

O/P Mode of The O/P 2

 

Time = 5 Sec, Momentary

5 6

Start & Stop Time

Nil ----- User Program Required

5 5

System Real-Time-Clock

Nil ----- User Program Required

9 4

Operation Modes 

Code = 0,Keypad Mode 

6 0

Personal Safety & Lock-out

Code = 1, 10 False Code/Card Lock-out 60 Sec

7 0

User Code Entry Mode

Code = 2, Manual Entry Mode

7 1

7 2

O/P Operation Announcer

7 3

Status LED Standby Flashing ON-

OFF

Code = 1, Flashing Enabled

8 0

Door Forced Open Warning & Timing

Code = 0, Warning Disabled

8 1

Door Propped-up Warning & Delay

Code = 0, Warning Disabled

9 0

Egress Delay & Warning

Code 1 = 0, Instant, No Delay

Code 2 = 1, Momentary Contact without Warning

Code = 1, Pacifier Tone ON

Code = 1 Sec, Notification Beep ON

Pacifier Tones ON-OFF Selection

THE DEFAULT VALUES AFTER REFRESHING

NOTE:

The DAP Code 

2 8 2 8

 and the Refreshing Code 

9 9 9 9 

are fixed in the operating system program. 

It can not be changed in any ways.

16

45

PROGRAMMING SUMMARY CHART

LOCATION

FUNCTION

ENTRY LIMITS & CODE 

OPTIONS

CODE ENTRY

FACTORY 

DEFAULT

0 1

Master Code

4-8 Digits



 

MASTER CODE

 

NIL

0 2

Super User 

Code

4-8 Digits



 

SUPER USER CODE

 

NIL

0 3

Common User 

Code for 

 

O/P 1

4-8 Digits



 

COMMON USER CODE 1

 

NIL

NIL

0 4

Common User 

Code for 

O/P 2



 

COMMON USER CODE 2

 

1 0 

User 

Codes / Cards for 

 

O/P 1

CODE 1 

-

 MEDIA:

1---EM Card

2---Private User Code

3---EM Card+Sec User Code

4---EM Card+Com User Code

5---Deletion of User Code

CODE 2 

CODE 3 

USER CODES/

                   CARDS :

 

4-8 Digits/Cards 

USER ID:

000-999---Group 1(10)

001-100---Group 2(20)



 

CODE1

 

CODE2

 

CODE3

 

NIL

2 0 

User 

Codes / Cards for 

 

O/P 2



 

NIL

4 0

Visitor Codes

 

CODE 1 

VISITOR ID:

 

01-50

CODE 2 

VALID PERIOD:

 

00---One Time

01-99 Hours

CODE 3 

VISITOR CODE:

 

4-8 Digits



NIL

4 1

Duress Code for O/P 1

CODE ID 

-

 O/P 1:

 01-50

CODE ID 

-

 O/P 2:

 01-10

DURESS CODE:

 4-8 Digits



 

CODE ID

 

DURESS CODE

CODE ID

 

 

 

NIL

4 2

Duress Code for O/P 2



 

 

 

NIL

5 1

O/P Mode for O/P 1

OUTPUT MODE & TIME:

0--- Start / Stop

1---99999 Seconds

START TIME:

00:00-23:59

STOP TIME:

00:00-23:59

5 6

Start & Stop Times

for Inhibition



STOP TIME

START TIME

NIL

CURRENT REAL TIME:

00:00-23:59

5 5

Real-Time-Clock



CURRENT TIME

NIL



 

O/P MODE & TIME

 

5 Seconds

5 2

O/P Mode for O/P 2



 

O/P MODE & TIME

 

5 Seconds

CODE1

 

CODE2

 

CODE3

CODE1

 

CODE2

 

CODE3

 

DURESS CODE

6 0

Personal Safety & 

 

Lock-Up

LOCK-UP CODE:

1---10 Trial, Lock-Up 60 Sec.

2---10 Trial, Activates Duress

5-10---5-10 Trial, Lock-Up 15 

Minutes

00---No Lock-Up



 

LOCK-UP CODE

 

Code = 1, 

10 Trials, 

Lock-Up 60 

Seconds

7 0

Code Entry Mode

ENTRY MODE:

1---Auto Mode

2---Manual Mode



 

ENTRY MODE

 

Mode = 

2, Manual  

Mode

Summary of Contents for DK-2836A

Page 1: ...B User Manual MK II FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM INSTALLATIONS AEI PROTECT ON SYSTEMS LIMITED www apo hk com Ver 201710_V5 VANDAL RESISTANT TRI TECH ACCESS CONTROL KEYPAD WITH CAR...

Page 2: ...User Code Common User Codes for Output 1 2 User Codes Card For Output 1 2 Examples Programming And Operation Visitor Codes For Output 1 Only Duress Codes For Outputs 1 2 Operation And Function of The...

Page 3: ...means that no electricity is connected to it It is prepared for free connections The Relay Output contacts provided in this keypad system are dry contacts N C Normally Closed the contact is closed cir...

Page 4: ...k Actuation Control Output Relay 2 2A Rating N C N O Contacts for External Door Bell Actuation Control A member of the Tri Tech series keypads compatible with the optional controllers reader keypads f...

Page 5: ...to ground when duress code is entered You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or connect it to a 24 hour Normally Open protection zone of an alarm system Only on...

Page 6: ...net Housing Die Cast Zinc Alloy Protection Bracket Faceplate Material Stainless Steel APPLICATION HINTS FOR THE AUXILIARY TERMINALS B DOOR SENS With the help of a Normally Closed door position sensor...

Page 7: ...oded operation It is compatible with the auxiliary readers AR 2802 and the auxiliary reader keypads AR 2806 AR 2807 AR 2809 Total 3 auxiliary readers or reader keypads can be connected in parallel wit...

Page 8: ...ith all the input and output installations connecting to it The DK 2836 manages the data in the system with its Data I O Bus The decoder operates the door lock and the appliances directly according to...

Page 9: ...o open during the operation While one of the doors is opened the other door keeps close until the open door is re closed It prevents the unauthorized people dashing into a protected area while the doo...

Page 10: ...ormation 14 DATA I O Data Input Output Communication Bus Data I O port is prepared for setting up a data bus for the connection of the auxiliary reader keypads and the split decoder in system expansio...

Page 11: ...essful Key Entry 1 Beep 1 Flash 3 Successful Code Card Entry 2 Beeps 2 Flashes 4 Unsuccessful Code Card Entry 5 Beeps 5 Flashes 5 Power Up Delay Continuous Beeps Continuous Flashes 6 Output Relay Acti...

Page 12: ...r Code Operation Media 3 A secondary user code can be repeatedly used for a group of cards in a department Owner can make a proprietary department code for each department in a company Only the staff...

Page 13: ...o open the door Card with proprietary user code approach is ideal for the area that high security is the main concern This operation mode can also report Duress Alarm by keying in the duress code inst...

Page 14: ...gned for setting the keypad to programming mode with DAP code See the details of DAP CODE 2 8 2 8 below 1 The keypad gives continuous beeps for 1 minute after power up 2 The power up delay can be stop...

Page 15: ...to normal opration after programming DIRECT ACCESS TO PROGRAMMING MODE WITH DAP CODE 2 8 2 8 In case the Master Code is forgotten apply the following procedures precisely to set keypad into programmi...

Page 16: ...system program It can not be changed in any ways 16 45 PROGRAMMING SUMMARY CHART LOCATION FUNCTION ENTRY LIMITS CODE OPTIONS CODE ENTRY FACTORY DEFAULT 0 1 Master Code 4 8 Digits MASTER CODE NIL 0 2...

Page 17: ...used with the EM Card It is for example here only f Confirm the Card Code is stored 2 beeps 6 Record an EM Card Commom User Code to Operate The Output 1 for Door Open a b c d e a 10 Programming Locat...

Page 18: ...eps 3 2 8 9 is a Master Code for example here only It replaces the old master code 0000 OPERATION AND FUNCTIONS OF THE SUPER USER CODE 1 Operate Output 1 and 2 The operation of the Super User Code is...

Page 19: ...ops in toggle with the following code entry It can be done before or during the inhibition period Door Lock Operation Resumes Start Stop in Toggle NOTE The INHIBIT LED Red is ON in inhibition and turn...

Page 20: ...ep confirms the entry EXAMPLES Example 1 Set Egress Button in Momentary contact of 5 seconds with delay warning beep a b c d a Egress function programming b Momentary contact with warning c Delay time...

Page 21: ...ber to enable 1 of the 6 configurations described below Momentary Contact Mode without Warning Default Momentary Contact Mode with Warning Beep Momentary Contact Mode with Warning Beep Alarm Holding C...

Page 22: ...peration mode a b a Key in the Private User Code 1 2 3 4 b Confirm it with the key Output 2 activates Read Card Read Card 22 High Traffic Passage A short buffer time may be necessary for opening a doo...

Page 23: ...e to prevent unattended leaving shoplifting and unauthorized use of the emergency exits The Intelligent Egress Button can be programmed to do something to get attention from the person on duty before...

Page 24: ...f users including the Codes and Cards can be cleared with the following command a b c a The User Group 1 10 is selected to be cleared 20 for Group 2 b Key in the Group Deletion Command 0 9 9 9 c Confi...

Page 25: ...ation 72 1 LOCATION Key in Location 2 FUNCTION MODES FOR OUTPUT ANNOUNCER Output announcer gives notification beep on the operation status of the outputs There are two notification modes available for...

Page 26: ...all User Codes must be in 5 digits as well All other User Codes not in 5 digits become invalid When the number of digits reaches the system will check the User Code automatically Good for high traffic...

Page 27: ...e code entry The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry Always set a Duress Code that is easy to remember in Panic Situation Only one number differ...

Page 28: ...or Output 1 b Duress Code ID c The Duress Code e Entry Confirmation iii Pause the real time inhibition manually The real time inhibition can be stopped temporarily if require such as the staff work ov...

Page 29: ...ent in emergency START STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 Location 56 Setting with start and stop times into the keypad the real time inhibition period for output 1 will recycle daily until t...

Page 30: ...4 hour real time clock provides the daily time base for starting and stopping the function of inhibition to relay output 1 mainly for electric door lock strike No real time clock setting is required i...