7) Example 7 – Report A Duress While Using EM Card :
The Duress Codes are Prime User Codes in the system. In the “EM Card + Secondary User Code”
or “EM Card + Common User Code” operation, they can be used to replace the “Secondary User
Code” or the “Common User Code” to operate the specific output and report a duress alarm event.
Programming is not required. The system has this function automatically while Duress Code exists.
Operation : (while the system is in the operation mode)
(a) (b) (c)
(a) Read the EM card. Two-beep confirms the reading and 30 seconds waiting time is given for
entry of the Duress Code, the Amber LED keeps flashing
(b) Key in one of the Duress Codes for the specific output (the Code programmed in “Location 41
and 42 for Output 1 and 2 respectively)
(c) Confirm it with the # key. The specific Output activates in a normal way and the Duress Output
also activates to report Duress Event to an alarm system.
NOTE:
The Duress Event can not be reported if the operation mode is EM Card alone. It is required
Duress Code
Read Card
to key in the Duress Code directly instead of EM card to report Duress Event.
5) Example 5 -- Delete An User Code & / or EM Card (for O/P 1 or 2) :
i) Delete An User Code or A Lost EM Card
(a) (b) (c) (d)
(a) Key in the User Group that the User ID belongs to. “10” for Group 1, “20” for Group 2
(b) Key in “5” that is the Command Code for making a deletion
(c)
Key in the User ID that stored the User Code, the lost EM card or the EM Card+User Code
(d) Press the # key. Two-beep confirms a valid entry and the Code and/or Card in that User ID is
cleared
ii) Delete an EM Card
(a) (b) (c) (d)
(a) Key in the User Group that the EM Card belongs to. “1 0” for Group 1, “2 0” for Group 2
(b) Key in “5” that is the Command Code for making a deletion
(c) Read the EM card. One-beep confirms the reading. Read the Card only also makes a valid deletion
to the Card working with the Common User Code or the Secondary User Code
(d) Press the # key. Two-beep confirms a valid entry. The EM Card in that User ID is cleared. Key in
the User ID is not required.
6) Example 6 – Clear The Whole Group of Users :
Whole group of users including the Codes and Cards can be cleared with the following command.
(a) (b) (c)
(a) The User Group 1 – “10” is selected to be cleared. “20” for Group 2
(b) Key in the Group Deletion Command, 0 9 9 9
(c) Confirm the deletion with #. All the User Codes and Cards in Group 1 are cleared. It takes few
seconds to a minute to complete depending on the data stored.
User ID
Read Card
DOOR PROPPED-UP WARNING & THE DELAY TIME (Location 81)
(1) LOCATION
Key in Location
(2) FUNCTION MODES FOR DOOR PROPPED-UP WARNING
If somebody opened the door and left it open longer than the allowable delay time, the keypad will
generate door propped-up warning
until the door is re-closed
. There is warning beeps from the
keypad only but it does not activate the alarm output. This function works with a door position
sensing switch equipped on the door.
---
Door Propped-up Warning OFF – (Default)
-
---
Door Propped-up Warning ON & The Delay Time
The Delay Time can be 1 to 999 seconds. It is the allowed time for door open without starting
warning.
(3) VALIDATION
Press key once. Two-beep confirms the entry
FUNCTION MODES
VALIDATION
LOCATION
or
-
(2)
(3)
(1)
DOOR FORCED OPEN WARNING & TIMING (Location 80)
(1) LOCATION
Key in Location
(2) FUNCTION MODES FOR DOOR FORCED OPEN WARNING
The Door Forced Open Warning function works with a Door Position Sensing switch equipped on the
door (usually a magnetic contact). Once a Timing Figure is put into the Function Mode box, the
warning mode is enabled.
---
Door Forced Open Warning OFF – (Default)
-
---
Door Forced Open Warning & Alarm Enabled & Timing
The Timing Figure for the Warning can be 1-999 seconds. The keypad generates the door forced
open warning beeps and activates the alarm output (Terminal 7) instantly if the door is forced to
open without a valid User Code/Card or pressing of Egress Button. The beeps and alarm will last as
long as the time set on the timer and it can be stopped at anytime with an User Code/Card in Group
1 before the end of the time.
The Manner of The Door Forced Open Warning:
a) The door is forced to open (without using Code or Egress Button) –
Warning & Alarm
b) The door is opened with Code –
No Warning or Alarm
c) The door is opened with Egress Button –
No Warning or Alarm
(3) VALIDATION
Press key once. Two-beep confirms the entry
FUNCTION MODES
VALIDATION
LOCATION
or
-
(2)
(3)