7) Example 7 – Report A Duress While Using EM Card :

The Duress Codes are Prime User Codes in the system. In the “EM Card + Secondary User Code” 

or “EM Card + Common User Code” operation, they can be used to replace the “Secondary User 

Code” or the “Common User Code” to operate the specific output and report a duress alarm event. 

Programming is not required. The system has this function automatically while Duress Code exists.

Operation : (while the system is in the operation mode)

  
           (a)                        (b)                    (c)
(a) Read the EM card. Two-beep confirms the reading and 30 seconds waiting time is given for 

entry of the Duress Code, the Amber LED keeps flashing

(b) Key in one of the Duress Codes for the specific output (the Code programmed in “Location 41 

and 42 for Output 1 and 2 respectively)

(c) Confirm it with the # key. The specific Output activates in a normal way and the Duress Output 

also activates to report Duress Event to an alarm system.      

NOTE:

 The Duress Event can not be reported if the operation mode is EM Card alone. It is required 

Duress Code

Read Card

to key in the Duress Code directly instead of EM card to report Duress Event.

5) Example 5 -- Delete An User Code & / or EM Card (for O/P 1 or 2) :

i) Delete An User Code or A Lost EM Card

         (a)     (b)         (c)        (d)
(a) Key in the User Group that the User ID belongs to. “10” for Group 1, “20” for Group 2

(b) Key in “5” that is the Command Code for making a deletion

(c)

 

Key in the User ID that stored the User Code, the lost EM card or the EM Card+User Code

(d) Press the # key. Two-beep confirms a valid entry and the Code and/or Card in that User ID is 

cleared      

ii) Delete an EM Card

          (a)      (b)             (c)           (d)
(a) Key in the User Group that the EM Card belongs to. “1 0” for Group 1, “2 0” for Group 2

(b) Key in “5” that is the Command Code for making a deletion

(c) Read the EM card. One-beep confirms the reading. Read the Card only also makes a valid deletion 

to the Card working with the Common User Code or the Secondary User Code

(d) Press the # key. Two-beep confirms a valid entry. The EM Card in that User ID is cleared. Key in 

the User ID is not required. 

      

6) Example 6 – Clear The Whole Group of Users :

Whole group of users including the Codes and Cards can be cleared with the following command.

          (a)              (b)           (c)
(a) The User Group 1 – “10” is selected to be cleared.  “20” for Group 2

(b) Key in the Group Deletion Command, 0 9 9 9

(c) Confirm the deletion with #. All the User Codes and Cards in Group 1 are cleared. It takes few 

seconds to a minute to complete depending on the data stored.

User ID

Read Card

DOOR PROPPED-UP WARNING & THE DELAY TIME                                (Location 81)

(1) LOCATION 

Key in Location

(2) FUNCTION MODES FOR DOOR PROPPED-UP WARNING

If somebody opened the door and left it open longer than the allowable delay time, the keypad will 

generate door propped-up warning 

until the door is re-closed

. There is warning beeps from the 

keypad only but it does not activate the alarm output. This function works with a door position 

sensing switch equipped on the door.

 --- 

Door Propped-up Warning OFF – (Default)

 - 



 ---

 Door Propped-up Warning ON & The Delay Time

The Delay Time can be 1 to 999 seconds. It is the allowed time for door open without starting  

warning.

(3) VALIDATION

Press      key once. Two-beep confirms the entry

FUNCTION MODES

VALIDATION

LOCATION

 or 

 - 





(2)

(3)

(1)



DOOR FORCED OPEN WARNING & TIMING                                              (Location 80)

(1) LOCATION 

Key in Location

(2) FUNCTION MODES FOR DOOR FORCED OPEN WARNING

The Door Forced Open Warning function works with a Door Position Sensing switch equipped on the 

door (usually a magnetic contact). Once a Timing Figure is put into the Function Mode box, the 

warning mode is enabled.

 --- 

Door Forced Open Warning OFF – (Default)

 - 



 --- 

Door Forced Open Warning & Alarm Enabled & Timing

The Timing Figure for the Warning can be 1-999 seconds. The keypad generates the door forced 

open warning beeps and activates the alarm output (Terminal 7) instantly if the door is forced to 

open without a valid User Code/Card or pressing of Egress Button. The beeps and alarm will last as 

long as the time set on the timer and it can be stopped at anytime with an User Code/Card in Group 

1 before the end of the time.

The Manner of The Door Forced Open Warning:

a) The door is forced to open (without using Code or Egress Button) – 

Warning & Alarm

b) The door is opened with Code – 

No Warning or Alarm

c) The door is opened with Egress Button – 

No Warning or Alarm

(3) VALIDATION

Press   key once. Two-beep confirms the entry

FUNCTION MODES

VALIDATION

LOCATION

 or 

 - 





(2)

(3)

(1)



Summary of Contents for DK-2836A

Page 1: ...B User Manual MK II FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM INSTALLATIONS AEI PROTECT ON SYSTEMS LIMITED www apo hk com Ver 201710_V5 VANDAL RESISTANT TRI TECH ACCESS CONTROL KEYPAD WITH CAR...

Page 2: ...User Code Common User Codes for Output 1 2 User Codes Card For Output 1 2 Examples Programming And Operation Visitor Codes For Output 1 Only Duress Codes For Outputs 1 2 Operation And Function of The...

Page 3: ...means that no electricity is connected to it It is prepared for free connections The Relay Output contacts provided in this keypad system are dry contacts N C Normally Closed the contact is closed cir...

Page 4: ...k Actuation Control Output Relay 2 2A Rating N C N O Contacts for External Door Bell Actuation Control A member of the Tri Tech series keypads compatible with the optional controllers reader keypads f...

Page 5: ...to ground when duress code is entered You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or connect it to a 24 hour Normally Open protection zone of an alarm system Only on...

Page 6: ...net Housing Die Cast Zinc Alloy Protection Bracket Faceplate Material Stainless Steel APPLICATION HINTS FOR THE AUXILIARY TERMINALS B DOOR SENS With the help of a Normally Closed door position sensor...

Page 7: ...oded operation It is compatible with the auxiliary readers AR 2802 and the auxiliary reader keypads AR 2806 AR 2807 AR 2809 Total 3 auxiliary readers or reader keypads can be connected in parallel wit...

Page 8: ...ith all the input and output installations connecting to it The DK 2836 manages the data in the system with its Data I O Bus The decoder operates the door lock and the appliances directly according to...

Page 9: ...o open during the operation While one of the doors is opened the other door keeps close until the open door is re closed It prevents the unauthorized people dashing into a protected area while the doo...

Page 10: ...ormation 14 DATA I O Data Input Output Communication Bus Data I O port is prepared for setting up a data bus for the connection of the auxiliary reader keypads and the split decoder in system expansio...

Page 11: ...essful Key Entry 1 Beep 1 Flash 3 Successful Code Card Entry 2 Beeps 2 Flashes 4 Unsuccessful Code Card Entry 5 Beeps 5 Flashes 5 Power Up Delay Continuous Beeps Continuous Flashes 6 Output Relay Acti...

Page 12: ...r Code Operation Media 3 A secondary user code can be repeatedly used for a group of cards in a department Owner can make a proprietary department code for each department in a company Only the staff...

Page 13: ...o open the door Card with proprietary user code approach is ideal for the area that high security is the main concern This operation mode can also report Duress Alarm by keying in the duress code inst...

Page 14: ...gned for setting the keypad to programming mode with DAP code See the details of DAP CODE 2 8 2 8 below 1 The keypad gives continuous beeps for 1 minute after power up 2 The power up delay can be stop...

Page 15: ...to normal opration after programming DIRECT ACCESS TO PROGRAMMING MODE WITH DAP CODE 2 8 2 8 In case the Master Code is forgotten apply the following procedures precisely to set keypad into programmi...

Page 16: ...system program It can not be changed in any ways 16 45 PROGRAMMING SUMMARY CHART LOCATION FUNCTION ENTRY LIMITS CODE OPTIONS CODE ENTRY FACTORY DEFAULT 0 1 Master Code 4 8 Digits MASTER CODE NIL 0 2...

Page 17: ...used with the EM Card It is for example here only f Confirm the Card Code is stored 2 beeps 6 Record an EM Card Commom User Code to Operate The Output 1 for Door Open a b c d e a 10 Programming Locat...

Page 18: ...eps 3 2 8 9 is a Master Code for example here only It replaces the old master code 0000 OPERATION AND FUNCTIONS OF THE SUPER USER CODE 1 Operate Output 1 and 2 The operation of the Super User Code is...

Page 19: ...ops in toggle with the following code entry It can be done before or during the inhibition period Door Lock Operation Resumes Start Stop in Toggle NOTE The INHIBIT LED Red is ON in inhibition and turn...

Page 20: ...ep confirms the entry EXAMPLES Example 1 Set Egress Button in Momentary contact of 5 seconds with delay warning beep a b c d a Egress function programming b Momentary contact with warning c Delay time...

Page 21: ...ber to enable 1 of the 6 configurations described below Momentary Contact Mode without Warning Default Momentary Contact Mode with Warning Beep Momentary Contact Mode with Warning Beep Alarm Holding C...

Page 22: ...peration mode a b a Key in the Private User Code 1 2 3 4 b Confirm it with the key Output 2 activates Read Card Read Card 22 High Traffic Passage A short buffer time may be necessary for opening a doo...

Page 23: ...e to prevent unattended leaving shoplifting and unauthorized use of the emergency exits The Intelligent Egress Button can be programmed to do something to get attention from the person on duty before...

Page 24: ...f users including the Codes and Cards can be cleared with the following command a b c a The User Group 1 10 is selected to be cleared 20 for Group 2 b Key in the Group Deletion Command 0 9 9 9 c Confi...

Page 25: ...ation 72 1 LOCATION Key in Location 2 FUNCTION MODES FOR OUTPUT ANNOUNCER Output announcer gives notification beep on the operation status of the outputs There are two notification modes available for...

Page 26: ...all User Codes must be in 5 digits as well All other User Codes not in 5 digits become invalid When the number of digits reaches the system will check the User Code automatically Good for high traffic...

Page 27: ...e code entry The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry Always set a Duress Code that is easy to remember in Panic Situation Only one number differ...

Page 28: ...or Output 1 b Duress Code ID c The Duress Code e Entry Confirmation iii Pause the real time inhibition manually The real time inhibition can be stopped temporarily if require such as the staff work ov...

Page 29: ...ent in emergency START STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 Location 56 Setting with start and stop times into the keypad the real time inhibition period for output 1 will recycle daily until t...

Page 30: ...4 hour real time clock provides the daily time base for starting and stopping the function of inhibition to relay output 1 mainly for electric door lock strike No real time clock setting is required i...

Reviews: