VISITOR CODES  (FOR OUTPUT 1 ONLY)                                                  (Location 40)

The Visitor Codes are temporary user codes for Output 1 (mainly for door strike in access control). 

They can be programmed as 

“One Time Codes”

 or 

“Codes with Time Limit”

. The Visitor Codes 

will be cleared automatically after use if they are one time codes, or, when the allowed time 

expires.

(1) LOCATION

Key in Location

(2) VISITOR ID

                     

  

--- 

50 Visitor IDs for the 50 visitor codes. They are Two-digit numbers

                      

---

 

(3) VALID PERIOD

The codes in this box 

MUST

 be two digits and they represent the time of operation.

           

 ---  One Time Code

One Time Code has no time limit but it can only be used for ONCE. It is cleared after 
use.

            -           

 --- Time Limit in Hour(s)

The Visitor Code can be set with the valid time limit of 1 Hour to 99 Hours with 

a two-digit number of 01 to 99. The visitor code is cleared when the time limit 

reaches.

4-8 DIGITS



 



-





 or 



-



VISITOR CODE

VALIDATION

LOCATION

VISITOR ID

VALID PERIOD

(5)

(4)

(3)

(2)

(1)



-

Clear all the Visitor Codes in Location 40. Please see the Programming example 

below for the details.

(4) VISITOR CODES 

NOTE: All Visitor Codes will be cleared after power down to prevent extension/confusion of 
their valid time limit.

(5) VALIDATION

Press       key once. Two-beep confirms the entry.

The Visitor Codes can be 4-8 digits for Manual Mode code entry.
The Visitor Codes MUST be in the same digit length with the Master Code for Auto Mode code entry.
The Visitor Codes can not reset Duress Output.
When a new Visitor Code is put in the same Code box, the old code is replaced.

OUTPUT OPERATION ANNOUNCER                                                          (Location 72)

(1) LOCATION 

Key in Location

(2) FUNCTION MODES FOR OUTPUT ANNOUNCER

Output announcer gives notification beep on the operation status of the outputs. There are two 

notification modes available for the selection.The notification is also OFF while the Pacifier Tone OFF 

mode in the Location 71 is selected.

      --- 

No Notification

The output operation notification is OFF but does note affect the normal pacifier tones.   

    --- 

1 Second Long Notification -- (Default)

1 second notification beep is given when the output relay activates. It is prepared to notify the 

person outside the door when the lock is released and the door can be opened. It is good for door 

lock that gives no sound when it activates, such as a magnetic lock.

 --- 

2 Short Beeps Notification

2 short beeps notification is given when the output relay activates.

(3) VALIDATION

Press  

 

key once. Two-beep confirms the entry

STATUS LED FLASHING ON-OFF DURING STANDBY                               (Location 73)

                                                                                                                                                   

(1) LOCATION 

Key in Location 

(2) FUNCTION MODES FOR STANDBY FLASHING LIGHT

Some people find the flashing light of the status LED (the amber LED) is annoying during standby, 

especially at the night time. The standby flashing can be ON-OFF with the setting here.

 --- 

Standby Flashing ON -- (Default)

The Status LED gives Standby Flashing all the time. It also gives the light indications showing the 

operation status of the system.

  --- 

Standby Flashing OFF

The Standby Flashing is OFF but it does not affect the system status indications.

(3) VALIDATION

Press 

 

 

key once. Two-beep confirms the entry

FUNCTION MODES

VALIDATION

LOCATION

 or 



(2)

(3)

(1)

FUNCTION MODES

VALIDATION

LOCATION

 or 



(2)

(3)

(1)





NOTE:

In multi-station operation, the output announcer only goes to the keypad that has been operated but 

not all the keypads in the system.

Summary of Contents for DK-2836A

Page 1: ...B User Manual MK II FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM INSTALLATIONS AEI PROTECT ON SYSTEMS LIMITED www apo hk com Ver 201710_V5 VANDAL RESISTANT TRI TECH ACCESS CONTROL KEYPAD WITH CAR...

Page 2: ...User Code Common User Codes for Output 1 2 User Codes Card For Output 1 2 Examples Programming And Operation Visitor Codes For Output 1 Only Duress Codes For Outputs 1 2 Operation And Function of The...

Page 3: ...means that no electricity is connected to it It is prepared for free connections The Relay Output contacts provided in this keypad system are dry contacts N C Normally Closed the contact is closed cir...

Page 4: ...k Actuation Control Output Relay 2 2A Rating N C N O Contacts for External Door Bell Actuation Control A member of the Tri Tech series keypads compatible with the optional controllers reader keypads f...

Page 5: ...to ground when duress code is entered You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or connect it to a 24 hour Normally Open protection zone of an alarm system Only on...

Page 6: ...net Housing Die Cast Zinc Alloy Protection Bracket Faceplate Material Stainless Steel APPLICATION HINTS FOR THE AUXILIARY TERMINALS B DOOR SENS With the help of a Normally Closed door position sensor...

Page 7: ...oded operation It is compatible with the auxiliary readers AR 2802 and the auxiliary reader keypads AR 2806 AR 2807 AR 2809 Total 3 auxiliary readers or reader keypads can be connected in parallel wit...

Page 8: ...ith all the input and output installations connecting to it The DK 2836 manages the data in the system with its Data I O Bus The decoder operates the door lock and the appliances directly according to...

Page 9: ...o open during the operation While one of the doors is opened the other door keeps close until the open door is re closed It prevents the unauthorized people dashing into a protected area while the doo...

Page 10: ...ormation 14 DATA I O Data Input Output Communication Bus Data I O port is prepared for setting up a data bus for the connection of the auxiliary reader keypads and the split decoder in system expansio...

Page 11: ...essful Key Entry 1 Beep 1 Flash 3 Successful Code Card Entry 2 Beeps 2 Flashes 4 Unsuccessful Code Card Entry 5 Beeps 5 Flashes 5 Power Up Delay Continuous Beeps Continuous Flashes 6 Output Relay Acti...

Page 12: ...r Code Operation Media 3 A secondary user code can be repeatedly used for a group of cards in a department Owner can make a proprietary department code for each department in a company Only the staff...

Page 13: ...o open the door Card with proprietary user code approach is ideal for the area that high security is the main concern This operation mode can also report Duress Alarm by keying in the duress code inst...

Page 14: ...gned for setting the keypad to programming mode with DAP code See the details of DAP CODE 2 8 2 8 below 1 The keypad gives continuous beeps for 1 minute after power up 2 The power up delay can be stop...

Page 15: ...to normal opration after programming DIRECT ACCESS TO PROGRAMMING MODE WITH DAP CODE 2 8 2 8 In case the Master Code is forgotten apply the following procedures precisely to set keypad into programmi...

Page 16: ...system program It can not be changed in any ways 16 45 PROGRAMMING SUMMARY CHART LOCATION FUNCTION ENTRY LIMITS CODE OPTIONS CODE ENTRY FACTORY DEFAULT 0 1 Master Code 4 8 Digits MASTER CODE NIL 0 2...

Page 17: ...used with the EM Card It is for example here only f Confirm the Card Code is stored 2 beeps 6 Record an EM Card Commom User Code to Operate The Output 1 for Door Open a b c d e a 10 Programming Locat...

Page 18: ...eps 3 2 8 9 is a Master Code for example here only It replaces the old master code 0000 OPERATION AND FUNCTIONS OF THE SUPER USER CODE 1 Operate Output 1 and 2 The operation of the Super User Code is...

Page 19: ...ops in toggle with the following code entry It can be done before or during the inhibition period Door Lock Operation Resumes Start Stop in Toggle NOTE The INHIBIT LED Red is ON in inhibition and turn...

Page 20: ...ep confirms the entry EXAMPLES Example 1 Set Egress Button in Momentary contact of 5 seconds with delay warning beep a b c d a Egress function programming b Momentary contact with warning c Delay time...

Page 21: ...ber to enable 1 of the 6 configurations described below Momentary Contact Mode without Warning Default Momentary Contact Mode with Warning Beep Momentary Contact Mode with Warning Beep Alarm Holding C...

Page 22: ...peration mode a b a Key in the Private User Code 1 2 3 4 b Confirm it with the key Output 2 activates Read Card Read Card 22 High Traffic Passage A short buffer time may be necessary for opening a doo...

Page 23: ...e to prevent unattended leaving shoplifting and unauthorized use of the emergency exits The Intelligent Egress Button can be programmed to do something to get attention from the person on duty before...

Page 24: ...f users including the Codes and Cards can be cleared with the following command a b c a The User Group 1 10 is selected to be cleared 20 for Group 2 b Key in the Group Deletion Command 0 9 9 9 c Confi...

Page 25: ...ation 72 1 LOCATION Key in Location 2 FUNCTION MODES FOR OUTPUT ANNOUNCER Output announcer gives notification beep on the operation status of the outputs There are two notification modes available for...

Page 26: ...all User Codes must be in 5 digits as well All other User Codes not in 5 digits become invalid When the number of digits reaches the system will check the User Code automatically Good for high traffic...

Page 27: ...e code entry The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry Always set a Duress Code that is easy to remember in Panic Situation Only one number differ...

Page 28: ...or Output 1 b Duress Code ID c The Duress Code e Entry Confirmation iii Pause the real time inhibition manually The real time inhibition can be stopped temporarily if require such as the staff work ov...

Page 29: ...ent in emergency START STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 Location 56 Setting with start and stop times into the keypad the real time inhibition period for output 1 will recycle daily until t...

Page 30: ...4 hour real time clock provides the daily time base for starting and stopping the function of inhibition to relay output 1 mainly for electric door lock strike No real time clock setting is required i...

Reviews: