background image

DES-MAN ISS.3

Page

Section

Contents

1

i)

Introduction and Factory Defaults

2

ii)

Installation Instructions

iii)

Electrical and Data Connections; Circuit Schematic

3

iv)

Code Entry Mode

v)

Programming Mode

4

vi)

Adding and Removing Codes

5

vii)

Changing Door Strike Times

viii)

Setting the Invalid Code Penalty Time

6

ix)

Other Features. Remote Exit, Alarms, Relay 2,
Door Monitoring, Entry Under Duress, Alarm Signals

7

x)

Code Index Directory

8

xi)

Command Summary Chart

Storm AXS Strike Master Keypads provide comprehensive access control for all outdoor and
indoor locations. Door / system status is indicated by a high intensity LED light source and an
audible sounder. Storm AXS Strike Master Keypads are specified to survive in different service
environments, ranging from exposed unsupervised public locations to general service indoor
applications. Keypads in the Storm AXS Strike Master range are dimensionally and electrically
interchangeable. This allows users, entering codes at both outdoor or indoor access points, to
establish and maintain familiarity with the keypad features.

• Up to 50 user programmable 

entry codes

Entry Code indexing system provides a
directory of authorised code holders and
permits secure allocation and re-allocation
of 

entry codes

• 4, 5, or 6 digit 

entry codes

• One or two door control
• Anti-tamper alarm

Entry code entered under duress alarm

• Hidden 

entry code feature

• Forced door alarm

• Timed strike or latching door operation
• Timed lock out for repeated invalid code

input

• Remote switch exit facility 
• Fail (open) Fail (closed) option
• All weather resistant
• Two protection levels

– anti vandal keypad for unsupervised   

public, outdoor locations

– robust keypad for

regular outdoor / indoor locations

Default settings

FEATURE

FACTORY SET DEFAULT

‘Engineer’s’ code

111111

(For security, change default 

engineer’s code on installation)

Door 1 ‘Strike Time’

5 seconds

Door 2 ‘Strike Time’

5 seconds

Invalid code Penalty time

15 seconds

Relay 2 output

Set in ‘Alarms Mode’

Relay 2 Configuration

Relay Output set ‘normally open’

Door Sensor

Bridged. Remove wire bridge to enable this feature

The STORM AXS Strike Master Keypad is supplied with the following factory configured defaults.

t

m

r

o

Secure Keypads 
for access control

®

i) INTRODUCTION AND FACTORY DEFAULTS

Strike Master

Read this manual carefully before attempting to install, program or operate the 
STORM AXS Strike Master Keypad. After installation the Command Summary Chart at the
back of this manual can be used as a quick reference to programming and operating
command sequences.

Summary of Contents for Strike Master

Page 1: ...authorised code holders and permits secure allocation and re allocation of entry codes 4 5 or 6 digit entry codes One or two door control Anti tamper alarm Entry code entered under duress alarm Hidden entry code feature Forced door alarm Timed strike or latching door operation Timed lock out for repeated invalid code input Remote switch exit facility Fail open Fail closed option All weather resist...

Page 2: ...te On rough or uneven surfaces it may be necessary to apply a bead of silicone sealant around the inner face of the case at the point where it meets the mounting surface Where this method of sealing is necessary the thicker sealing gasket B must not be fitted ii INSTALLATION INSTRUCTIONS 2 Door Sensor Remote Exit Switch Door Strike Door call Bell Alarm Bell Klaxon Power Supply 10 Remote Switch To ...

Page 3: ...ng tone bleep to indicate that it has accepted the data and is ready for the next segment of the command If at any stage the keypad gives an error bleep decreasing pitch then the data entered is invalid The keypad will remain in programming mode but you must re enter the whole of the command sequence within which the error bleep occurred During everyday operation the keypad will be in code entry m...

Page 4: ...G CODES To add an entry code Enter the 2 digit index number max 50 Select door and mode of entry required for this entry code Door 1 Timed Enter Door 1 Latched Enter Door 2 Timed Enter Door 2 Latched Enter Enter 4 5 or 6 to correspond to no of digits in code Enter 4 or 5 or 6 Enter new code There are 2 options for removing codes remove a single code or remove all codes Remove an Index Field Enter ...

Page 5: ...ry mode if after twenty key presses a valid code has not been entered the keypad will be disabled for a pre set period of time This feature is intended to deter any attempt to gain unauthorised access by guessing the format of a valid code To set the Invalid Code Penalty Time log on then enter 7 to select the Invalid Code Penalty Time function Listen for the accept bleep Then enter a two digit num...

Page 6: ...pad must be isolated from the power for a minimum of 3 seconds to reset the alarm feature Note if the alarm function is used to indicate operator under duress then the alarm should be discreet i e situated in a remote location beyond the audible or visual range of an attacker or intruder The alarm feature can be used to interface with a centralised alarm system or to trigger a synthesised or pre r...

Page 7: ... 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 CODE INDEX NO CODE HOLDER NAME OF PERSON DEPARTMENT x CODE INDEX DIRECTORY DOOR TYPE OF CODE FEATURE 111111 change on installation 5 seconds 5 seconds 15 seconds Alarms Mode Normally Open record separately in safe location FACTORY SET DEFAULT OWNER SET CODES 1 2 LATCHED TIMED 7 DES MAN ISS 3 ...

Page 8: ...des Remove an Index Field Enter d Remove all Index Fields Enter d Enter Index number from which code is to be removed Enter vi REMOVING CODES vi ADDING CODES 2 3 Enter d 0 0 Enter d 1 Enter d 1 2 3 4 4 5 6 X X X X X X Start new command sequence Enter to d 1 8 LOG OFF NO Enter d 0 YES Index allocated delete fields Index allocated try another Index No Enter Strike Time in seconds Door 1 Door 2 To re...

Reviews: