DES-MAN ISS.3
Page
Section
Contents
1
i)
Introduction and Factory Defaults
2
ii)
Installation Instructions
iii)
Electrical and Data Connections; Circuit Schematic
3
iv)
Code Entry Mode
v)
Programming Mode
4
vi)
Adding and Removing Codes
5
vii)
Changing Door Strike Times
viii)
Setting the Invalid Code Penalty Time
6
ix)
Other Features. Remote Exit, Alarms, Relay 2,
Door Monitoring, Entry Under Duress, Alarm Signals
7
x)
Code Index Directory
8
xi)
Command Summary Chart
Storm AXS Strike Master Keypads provide comprehensive access control for all outdoor and
indoor locations. Door / system status is indicated by a high intensity LED light source and an
audible sounder. Storm AXS Strike Master Keypads are specified to survive in different service
environments, ranging from exposed unsupervised public locations to general service indoor
applications. Keypads in the Storm AXS Strike Master range are dimensionally and electrically
interchangeable. This allows users, entering codes at both outdoor or indoor access points, to
establish and maintain familiarity with the keypad features.
• Up to 50 user programmable
entry codes
•
Entry Code indexing system provides a
directory of authorised code holders and
permits secure allocation and re-allocation
of
entry codes
• 4, 5, or 6 digit
entry codes
• One or two door control
• Anti-tamper alarm
•
Entry code entered under duress alarm
• Hidden
entry code feature
• Forced door alarm
• Timed strike or latching door operation
• Timed lock out for repeated invalid code
input
• Remote switch exit facility
• Fail (open) Fail (closed) option
• All weather resistant
• Two protection levels
– anti vandal keypad for unsupervised
public, outdoor locations
– robust keypad for
regular outdoor / indoor locations
Default settings
FEATURE
FACTORY SET DEFAULT
‘Engineer’s’ code
111111
(For security, change default
engineer’s code on installation)
Door 1 ‘Strike Time’
5 seconds
Door 2 ‘Strike Time’
5 seconds
Invalid code Penalty time
15 seconds
Relay 2 output
Set in ‘Alarms Mode’
Relay 2 Configuration
Relay Output set ‘normally open’
Door Sensor
Bridged. Remove wire bridge to enable this feature
The STORM AXS Strike Master Keypad is supplied with the following factory configured defaults.
t
m
r
o
Secure Keypads
for access control
®
i) INTRODUCTION AND FACTORY DEFAULTS
Strike Master
Read this manual carefully before attempting to install, program or operate the
STORM AXS Strike Master Keypad. After installation the Command Summary Chart at the
back of this manual can be used as a quick reference to programming and operating
command sequences.