- 5 -
TSE-N 10.00 A. B.
599 50 84 90
EN
65 mm
11
12
14
16
17
45 mm
11
12
14
16
17
fS
fN
fS
fN
Pressure Switch
The pressure switch controls the water level.
Without water, contact 11 - 12 is closed.
fN
Switch point with level
65 mm Ws
Reset point with level
45 mm Ws
fS
Switch point with safety level
114 mm Ws
Reset point
90 mm Ws
The pressure switch is not adjustable.
Flow Heater
The flow heater heats the water to the required temperature. During
the wash cycle, water is contantly passing through the flow heater.
Power output
2100 W
Resistor
25
W
Protector
98 °C ± 5 K
Thermal fuse
260 °C
Circulation Pump
The circulation pump is driven by an asynchronous motor with an
auxiliary winding. The auxiliary winding ist in circuit with a 4 mF
capacitor. A tacho generator is used for speed control.
There are three speeds for rinsing.
2800 1/min, 2200 1/min, 1900 1/min, 1700 1/min, 1600 1/min,
Power
output
50 W.
Drain Pump
The drain pump is driven by a synchronous motor.
Power output 26 W.
Pump rate 15 l/min.