18. Program phase display, Status display
Program Phase Display PPD
-
PPD has always 3 steps
-
The PPD is realised by 3 LEDs (LD09 - LD11)
-
The program phases are actually defined: Clean - Dry - End
-
The displayed phases are related to the program cycle.
-
During the program selection, but before the real program start all relevant program phases
are shown in parallel by blinking LEDs.
-
E.g. in the Quick program or in the Prewash program, only PPD-LED LD09 is blinking, in all
other programs, LEDs LD09 and LD10.
-
After program start, only the LED for the actual program phase is ON.
-
The switch from one program phase to the following in done at the step change.
-
The display End (PPD-LED LD11) is not shown before the real program end, when the
timer has reached the end status.
-
With the PPD-LEDs LD09 - LD11 also different failures are displayed.
Status resp. Indication displays:
-
Displays are available depending on the device variant.
-
The display is done mainly by theLEDs LD13 and LD14.
If necessary due to design reasons, also other positions for the display are possible.
-
The display is realised by a permanent activation of the relevant LED.
-
The LEDs are ON beginning with the machine switched ON by the ON/OFF switch S0, till the
start of the program, this means, also during a possible StartTimeDelay phase.
Besides this, also from program end (PPD-LED End) till switching OFF the device.
-
The display LEDs are switched OFF during the complete program cycle!
-
LED-display SALT
o
ON if salt level is low
o
Switched off, after adding salt.
(Due to salt dissolution it can take some hours for switch OFF)
Comment LED-Display Salt is switched OFF if waterhardness WH1 is adjusted.
(no regeneration necessary)
-
LED-display RINSE AID
o
ON if rinse aid level is low
o
Switched off, after adding rinse aid.