- 11 -
TSE-N 10.00 A. B.
599 50 84 90
EN
6. All-Around Water Protection
Aqua-Control Inlet Hose
The inlet hose has a double-wall construction. The inner hose is equipped with a flow restrictor
built into the tap connection, and has a flow rate of 4 litres per minute. The inlet valve (1) is located
in the base of the dishwasher. The safety outer hose (12) is connected to the regeneration
chamber.
If the inner hose should burst, the water passes into the tub. The safety pressure switch
activates the drain pump and decreases the waterlevel down to normal level. An additional
overflow protection is a defined overflow through the regeneration chamber. The water flows into
the bottom tray and activates the float switch, which energises the drain pump.
This drains the
dishwasher preventing water damage.
Safety level
If the safety level is reached by over-fillling, the safety pressure switch starts the drain pump. The
water is only drained until it has reached the normal level because the reset point of the safety
pressure switch is above the switchpoint of the normal pressure switch.
Leakage Protection
The anti-flood switch in the base tray will activate the drain pump and drain the water from the tub
in the event of an internal leakage.
If the float switch is activated, all electric components are switched off except the electronic and
the drain pump.