- 30 -
TSE-N 10.00 A. B.
599 50 84 90
EN
Delete the customer service failure stack and LED-test
-
Press program button S2 and S3 simultaneous and keep them pressed until
switching the machine on with the ON/OFF button S0 .
-
For acknowledge, that the function is active, the LEDs LD1, LD2 and LD3 are blinking.
-
By pressing the program button S3 the function is started.
!! Attention: By starting the function, the failure memory is cleared automatically !!
-
All LEDs on the panel (max. LD1 to LD14) are switched ON simultaneous for approx. 1 se-
cond.
The activation of the LEDs is repeated twice, with a pause of 2 sec inbetween.
Afterwards the function is terminated.
-
The function can only be terminated before, by switching the machine OFF with the ON/OFF
button S0 .
22. Misuse and program interrupt
Parallel activation of 2 or more buttons
-
In terms of electronic control an exactly parallel activation of 2 or more buttons is not possible
in the practical use.
Button pressed too long (with already running program)
-
If a program button is pressed for more than 3 seconds, this can cause the running program
to be deleted or changed.
(see description Delete program, change program )
-
If an option button is activated, this causes no influence on the program run.
These buttons are deactivated after program start.
Failure during program run
-
The failure is displayed by a blinking program LED and the blinking PPD-LEDs according to
the defined code (see table). LEDs of probably choosen options remain ON.
Removeable failure - Water tap closed, Drain pump blocked
-
If the recognised failure is removeable by the user the machine automatically changes in a
PAUSE mode.
-
As soon as the failure, e.g. water tap closed is recognised, the program is stopped in the
actual step.
-
The control is waiting until the failure was removed (if possible).
-
To continue the program, the ON/OFF button S0 has to be switched OFF and ON.
-
The program cycle continues from the actual program step. No program information is lost.
-
Its not necessary to delete the program.
Other failures
-
All additional failures, which are partly also visible for the customer by the PPD-LEDs, are
listed in the table on page B12 in more detail.
Power fail
-
If a power fail occures, the machine shows the same behaviour as if switched OFF with the
ON/OFF button.
-
On power return, the machine shows the same behaviour as if switched ON with the ON/
OFF button.
-
The program continues from the last valid step. No program information is lost.
-
The program continues after power fail without additional button activation.