EKI-9226G Series User Manual
137
4.12
Modbus/TCP Mapping
The data map addresses of Advantech switches shown in the following table start
from Modbus address 30001 for function code 4.
In the given example, the address offset 0x1000 (hex) equals Modbus address
34097, while the address offset 0x1100 (hex) equals Modbus address 34353.
The information given by the Advantech is shown in hex mode.
4.12.1
Modbus/TCP Mapping Table
Catelog
Name
Data Type
Interpretation
Address
Offset (Hex)
Address
3X
Description
System Info
Vendor ID =
0x‘13FE
1 word 16 bits HEX
0x0000
30001
Vendor ID = 0x13FE
Unit ID = 0xFF 1 word 16 bits HEX
0x0001
30002
Unit ID = 0xFF
Product Code 1 word 16 bits HEX
0x0002
30003
Product Code
Vendor Name
= "Advantech"
16
words
32
chars
ASCII
0x0010
30017
Vendor Name =
"Advantech"
Word 0 Hi byte = 'A'
Word 0 Lo byte = 'd'
Word 1 Hi byte = 'v'
Word 1 Lo byte = 'a'
Word 2 Hi byte = 'n'
Word 2 Lo byte = 't'
Word 3 Hi byte = 'e'
Word 3 Lo byte = 'c'
Word 4 Hi byte = 'h'
Word 4 Lo byte = '\0'
Product Name
= "EKI-xxxx"
16
words
32
chars
ASCII
0x0020
30033
Product Name =
"EKI-xxxx"
Word 0 Hi byte = 'E'
Word 0 Lo byte = 'K'
Word 1 Hi byte = 'I'
Word 1 Lo byte = '-'
Word 2 Hi byte = 'x'
Word 2 Lo byte = 'x'
Word 3 Hi byte = 'x'
Word 3 Lo byte = 'x'
Word 4 Hi byte = '\0'
Firmware Ver
-
sion
2
words
32 bits HEX
0x020A
30523
Firmware Version
Word 0 Hi byte =
major
Word 0 Lo byte =
minor
Word 1 Hi byte =
release
Word 1 Lo byte =
build
Summary of Contents for EKI-9226G Series
Page 1: ...User Manual EKI 9226G Series 6xRJ45 20xSFP Port Full Gigabit L2 Managed Switch ...
Page 14: ...Chapter 1 1Product Overview ...
Page 19: ...Chapter 2 2Switch Installation ...
Page 34: ...Chapter 3 3Configuration Utility ...
Page 39: ...Chapter 4 4Managing Switch ...
Page 167: ...Chapter 5 5Troubleshooting ...