EKI-8500 Series User Manual
79
The following table describes the items in the PSFP SGI Status page.
4.4.4.4
FRER
4.4.4.4.1
FRER Status
The function provides an overview of the current FRER status.
1.
Navigate to
Monitor
>
TSN
>
FRER
and click
FRER Status
.
The FRER Status page displays.
Figure 4.57 FRER Status
The following table describes the items in the FRER Status page.
Item
Description
SGI ID
Displays the instance parameter.
Oper Gate Enabled Displays the active (true) / inactive (false) state of the parameter.
Oper Gate States
Displays the operational value indicating an open or closed gate.
Cycle Time
Numerator
Displays the operational numerator value indicating the cycle time as
a rational number of seconds. The numerator and denominator
together represent the cycle time as a rational number.
Cycle Time
Denominator
Displays the operational denominator value indicating the cycle time
as a rational number of seconds. The numerator and denominator
together represent the cycle time as a rational number.
Cycle Time
Extension
Displays the operational value of the CycleTimeExtension parameter
in nanoseconds.
Base Time
Displays the operational value of the BaseTime paramter. The value is
a representation of a PTPtime value, consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
Current Time
Displays the current time, in PTPtime, as maintained by the local
system.
Config Change Time Displays the PTPtime at which the next config change is scheduled to
occur.
Config Change Error Displays the number of times that a re-configuration of the traffic
schedule has been requested with the old schedule still running and
the requested base time was in the past.
Tick Granularity
Displays the granularity of the cycle time clock, represented as an
unsigned number of tenths of nanoseconds.
Config Pending
Displays the value of the ConfigPending state machine variable.
Oper IPV
Displays the operational value of the IPV parameter.
GCL Length
Displays the operational value of the ListMax parameter.
GCL Status
Displays the link to the GCL parameter status.
Auto-refresh
Check this box to refresh the page automatically. Automatic refresh
occurs every 3 seconds.
Refresh
Click
Refresh
to refresh the page immediately.
Item
Description
Instance
Displays the FRER instance.
Oper
Displays the operational state.
Green: active
Red: disabled or internal error detected.
Summary of Contents for EKI-8500 Series
Page 1: ...User Manual EKI 8500 Series Managed TSN Switch ...
Page 12: ...Chapter 1 1Product Overview ...
Page 19: ...Chapter 2 2Switch Installation ...
Page 35: ...Chapter 3 3Configuration Utility ...
Page 41: ...Chapter 4 4Managing Switch ...
Page 96: ...Chapter 5 5Troubleshooting ...