EKI-8500 Series User Manual
63
4.3.5.4.3
Stream Gate
This function allows you to inspect the current PSFP configurations, and possibly
change them as well.
1.
Navigate to
Configuration
>
TSN
>
PSFP
and click
Steam Gate
.
The PSFP Stream Gate parameters Configuration page displays.
Figure 4.37 PSFP Stream Gate parameters Configuration
The following table describes the items in the PSFP Stream Gate parameters
Configuration page.
SGI ID
Enter a string to indicate the Stream Gate Instance parameter
contains the index of an entry in the Stream Gate Table.
SDU Size
Enter a string to indicate the MaximumSDUSize parameter specifies
the maximum allowed frame size for the stream. Any frame exceeding
this value will be dropped. A value of 0 denote that the
MaximumSDUSize filter is disabled for this stream.
FMI ID
Enter a string to indicate the FlowMeterInstanceID parameter of an
entry in the Flow Meter Table. A value of -1 denotes that no flow meter
is assigned; zero or positive values denote flow meter IDs.
FMI Enable
Click to enable or disable (default) the FMI function.
Oversize Block
Enable
Click to enable or disable (default) the object to indicate whether the
StreamBlockedDueToOversizeFrame function is enabled (TRUE) or
disabled (FALSE).
Add New Entry
Click
Add New Entry
to add Stream Filter entry.
Save
Click
Save
to save changes.
Reset
Click
Reset
to undo any changes made locally and revert to
previously saved values.
Item
Description
Item
Description
Delete
Click
Delete
to remove the entry. It will be deleted during the next
save.
SGI ID
Enter an string to indicate a parameter for the Stream Gate ID.
Gate Enabled
Click to enable or disable (default) the Gate Enabled parameter
determines.
Gate States
Click the drop-down menu to select the administrative value of the
GateStates parameter (options: open, closed).
Cycle Time Value
Enter an string to indicate the administrative value of the cycle time for
the gate. The time may be specified in either milli seconds, micro
seconds or nano seconds as defined by the field Cycle Time unit.
Cycle Time unit
Enter an string to indicate the unit used for specifying the
administrative cycle time (values: ns, us or ms).
Cycle Time
Extension
Enter an string to indicate the administrative value of the
CycleTimeExtension parameter for the gate (value: unsigned integer
number of nanoseconds).