64
EKI-8500 Series User Manual
4.3.5.5
FRER
This function allows you to inspect the current FRER configurations
1.
Navigate to
Configuration
>
TSN
and click
FRER
The FRER Configuration Parameters page displays.
Figure 4.38 FRER Configuration Parameters
The following table describes the items in the FRER Configuration Parameters page.
Base Time
Enter an string to indicate the administrative value of the BaseTime
parameter for the gate (value: a representation of a PTPtime value,
consisting of decimal number of seconds since epoch). The time can
be given with a resolution of nine decimals.
Admin IPV
Click the drop-down menu to select the administrative value of the IPV
parameter for the gate. A value of -1 denotes the null value.
GCL Length
Enter an string to indicate the number of entries in the Gate Control
List.
GCL Configuration
Displays the configuration of the Gate Control List.
Enable Gate-closed-
due-to invalid-rx
Click to enable or disable (default) whether to close the gate if invalid
data is received.
Enable Gate-closed-
due-to octets-
exceeded
Click to enable or disable (default) whether to close the gate if too
many octets are received.
Config Change
The ConfigChange parameter signals the start of a configuration
change for the gate when it is set to TRUE. This should only be done
when the various administrative parameters are all set to appropriate
values.
Add New Entry
Click
Add New Entry
to add Stream Gate entry.
Save
Click
Save
to save changes.
Reset
Click
Reset
to undo any changes made locally and revert to
previously saved values.
Item
Description
Item
Description
Instance
Displays the instance of the identifier.
Mode
Displays the mode of operation: Generation or Recovery.
Enable
Displays the FRER instance status.
Ingress Streams
Enter a string to indicate the list of ingress stream IDs.
FRER VLAN
Displays the VLAN ID that ingress flows get classified to.
Egress Ports
Displays the port numbers that this FRER instance will hit.
Algorithm
Displays the algorithm used by Recovery function. Vector or match.
History Length
Displays the history length of vector algorithm.
Reset Timeout
Displays the reset timeout of Recovery function.
Take-no-sequence
If true, accept all frames whether they are R-tagged or not.
Individual
Displays the individual recovery status.
Terminate
Strip R-Tag from a frame before presenting it on egress.
Enable
Enable/disable Latent error detection.
Error Diff
Displays the latent error detection error difference.
Period
Displays the latent error detection period.