2.1.3. Transformer Options
You can connect an external isolation transformer to the Motor Supply AC Input to reduce the operating
voltage of the motor. Using a transformer can also reduce electrical noise.
Table 2-5:
Nominal Motor Operating Voltages / Required AC Voltages
AC Voltage
DC Voltage
28
40
56
80
115
160
230
320
Table 2-6:
Transformer Options
Transformer
Description
TV0.3-28-56-ST
Generate 28 or 56 VAC from 115 VAC or 230 VAC input source voltage. When
rectified by the drive, it produces a 40 or 80 VDC power bus.
TM3
Power up to 4 drives, providing 300 watts of power
TM5
Power up to 4 drives providing 500 watts of power
TV0.3-28
Generate 28 VAC from 115 VAC or 230 VAC input source voltage. When
rectified by the drive, it produces a 40 VDC power bus.
TV0.3-56
Generate 56 VAC from 115 VAC or 230 VAC input source voltage. When
rectified by the drive, it produces an 80 VDC power bus.
TV1.5, TV2.5, or TV5
1.5 kVA, 2.5 kVA, or 5 kVA isolation transformer; 115/230 VAC input; 28, 43,
56, 70, 115 VAC output
Figure 2-3:
Transformer Examples
2.1.3. Transformer Options
XC4 Hardware Manual
30
www.aerotech.com
Summary of Contents for Automation1 XC4
Page 1: ...Revision 2 01 Automation1 XC4 PWM Digital Drive HARDWARE MANUAL...
Page 12: ...This page intentionally left blank Agency Approvals XC4 Hardware Manual 12 www aerotech com...
Page 24: ...Figure 1 4 Dimensions EB1 1 2 2 Dimensions XC4 Hardware Manual 24 www aerotech com...
Page 71: ...Figure 2 36 PSO Interface XC4 Hardware Manual 2 5 Auxiliary I O Connector www aerotech com 71...
Page 120: ...Index XC4 Hardware Manual This page intentionally left blank 120 www aerotech com...