response:
>(cr)
An output byte with value 12h (00010010) is sent to the digital output module
at address 01h. Channels 1and 4 will be set to ‘ON’, and all other channels
will be set to ‘OFF’.
Note:
If any channel of the digital output module is configured as the output for an analog
input alarm, it cannot be reconfigured via digital output commands. Channels used for
analog input alarms always have a higher priority.