PCM-3718H/3718HG User's Manual
BASE+2 (write) - start and stop scan channels
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Value CH3
CH2
CH1
CH0
CL3
CL2
CL1
CL0
CH3 to CH0
Stop scan channel number
CL3 to CL0
Start scan channel number
The MUX scan register low nibble, CL3 to CL0, also acts as a pointer
when you program the A/D input range (see previous section). When
you set the MUX start channel to N, the range code written to the
register BASE+1 is for channel N.
Programming example
This C code sets the range for channel 5 to ±0.625 V:
OUTPORTB (BASE+2, 5); /* SET POINTER TO CHANNEL 5*/
OUTPORTB (BASE+1, 3); /* RANGE CODE FOR ±0.625V*/
Note:
The MUX start/stop channel changes each time when
you change the input range. Do not forget to reset the
MUX start and stop channels to the correct values
after your range setting.
4.5 Digital I/O Registers - BASE+3/11
The PCM-3718H/3718HG offers two 8-bit digital input/output
channels. These I/O channels use the input or output ports at address-
es Base+3 and BASE+11.
Summary of Contents for 3718HG
Page 1: ...PCM 3718H 3718HG PC 104 12 bit DAS Module with Programmable Gain User s manual ...
Page 2: ......
Page 5: ...1 General Information CHAPT ER ...
Page 13: ...2 Installation CHAPT ER ...
Page 21: ...3 Signal Connections CHAPT ER ...
Page 26: ...22 PCM 3718H 3718HG User s Manual ...
Page 27: ...4 Register Structure and Format CHAPT ER ...
Page 38: ...34 PCM 3718H 3718HG User s Manual ...
Page 39: ...5 A D Conversion CHAPT ER ...
Page 45: ...6 Digital Input Output CHAPT ER ...
Page 47: ...7 Programmable Pacer CHAPT ER ...
Page 57: ...8 Direct Memory Access Operation CHAPT ER ...
Page 60: ...56 PCM 3718H 3718HG User s Manual ...
Page 61: ...9 Calibration CHAPT ER ...
Page 64: ...60 PCM 3718H 3718HG User s Manual ...