Chapter 2 Installation 13
External input or DIO selection (JP3)
You can use pin 1 on connector P2 for connection to digital I/O line 0
or to an external A/D trigger source jumper setting. Jumper JP3
provides the selection, as shown below:
2.3 Connector Pin Assignments
The PCM-3718H/3718HG has two on-board 20-pin flat-cable
connectors (insulation displacement, mass termination).
The figure on page 5 shows locations of both connectors.
Refer to the table below for abbreviations of the pin assignment.
Abbreviations
Description
A/D S
Analog input (single-ended)
A/D H
Analog input high (differential)
A/D L
Analog input low (differential)
A.GND
Analog ground
DIO
Digital input/output
D.GND
Digital and power supply ground
DIO0
EXT
External trigger input
DIO0
EXT
Digital I/O line DIO 0 (default)