Chapter 2 Installation 11
addresses range from Hex 000 to Hex 3F0. Other devices in your
system can use some of these addresses.
We set the PCM-3718H/3718HG for a base address of Hex 300 at the
factory. If you need to adjust it to other address ranges, set SW1 by
referring to the following table:
Module I/O addresses (SW1)
Range (hex)
Switch position
1
2
3
4
5
6
000 - 00F
l
l
l
l
l
l
010 - 01F
l
l
l
l
l
¡
:
200 - 20F
¡
l
l
l
l
l
210 - 21F
¡
l
l
l
l
¡
:
*300 - 30F
¡
¡
l
l
l
l
:
3F0 - 3FF
¡
¡
¡
¡
¡
¡
¡
= Off
l
= On * = default
Note:
Switches 1-6 of the SW1 control the PC bus address
lines as follows:
Switch
1
2
3
4
5
6
Line
A9
A8
A7
A6
A5
A4