Chapter 9 Calibration 59
2. Adjust VR2 until the output from the card’s A/D converter flickers
between 0 and 1.
3. Connect an external DC voltage source with a value of 4094.5 LSB
to A/D channel 0.
4. Adjust VR1 until the A/D reading flickers between 4094 and 4095.
5. Repeat steps 2 to step 4, adjusting VR1 and VR2.
6. Select unipolar input configuration. Connect an external DC
voltage source with a value of 0.5 LSB to A/D channel 0. Adjust
VR3 until the reading of the A/D flickers between 0 and 1.