Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
◦ 1 = Pulse sync output on
• Bytes 2 and 3 = Reserved
Command
26
B0 = 2 sets these values.
172
report memory
mode
(subcommand 5)
Reports the unit memory mode settings.
Send 2 data bytes.
• Bytes 0 and 1 = 5 (report memory mode)
Returns 4 data bytes.
• Bytes 0 and 1 = Memory mode
◦ 0 = RAM
◦ 1 = NVRAM
• Bytes 2 and 3 = Reserved
Command
26
B0 = 5 sets these values.
2
4
193
report pulsing
frequency
Reports the pulsing frequency in Hz. Valid
values range from 10 Hz to 2000 Hz.The unit
may store pulsing frequency values in either
volatile or nonvolatile memory, depending on
the current memory mode (see command
26
).
The unit reports the value from the currently
active memory. This command is available in
both master and slave modes.
Returns 4 data bytes:
• Bytes 0 to 3 = Pulsing frequency in Hz.
Command
93
sets this value.
0
4
196
report pulsing duty
cycle
Reports the pulsing duty cycle in increments
of 1%. Valid values range from 10% to 90%.
The unit may store pulsing duty cycle values
in either volatile or nonvolatile memory,
depending on the current memory mode (see
command
26
). The unit reports the value
from the currently active memory. When
operating in slave mode, the unit returns CSR
12, Feature Not Available.
0
2
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑53