Table 3‑2. Electrical specifications (Continued)
Description
Specification
Reflected power limit
1500 W maximum
Delivered power into
mismatched loads
(Automatic load
mismatch protection,
unlimited load impedance
range, full frequency
range)
Generator maximum delivered power is based on reflected power
limit.
• Within VSWR 1.1:1 it is 2000 W
• Within VSWR 2.0:1 it is 2000 W
• Within VSWR 4.79:1 it is 2000 W
• Outside VSWR 4.79:1, maximum delivered power is restricted
by reflected power limit, 1500 W.
Delivered power setpoint
range
5 W to 2000 W
Frequency resolution
1 Hz
Regulation modes
selected by tool interface
Regulation modes:
• Forward power regulation mode
• Load power regulation mode
• Voltage regulation mode
Measured power accuracy
in full frequency range
and across full line
voltage range
Measured power accuracy is a combination of the generator and
measurement equipment accuracy.
These specifications were created per an AE test measurement
procedure. Using alternate test measurement devices and/or
procedures will result in deviations from the provided numbers and
values listed in this specification.
Measured power accuracy
into 50 Ω non-reactive
load
Power accuracy:
• ± 0.5 W of setpoint for 5 W to 50 W
• ± 1% of setpoint or ± 2 W, whichever is greater, when
operating at 400 kHz, into a 50 Ω, non-reactive load for 50 W
to 2000 W
• ± 1.5% of setpoint or ± 2 W, whichever is greater, over entire
frequency range when operated into a 50 Ω, non-reactive load,
for 50 W to 2000 W
Measured power accuracy
into 2:1 VSWR circle
Power accuracy:
• ± 1.5 W of setpoint for 5 W to 50 W, over entire frequency
range
• ± 2.5% of setpoint or ± 2 W for 50 W to 2000 W, whichever is
greater, over entire frequency range
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Specifications
3‑4